Brooklyn East New York-New Lots
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-03835-0042), so they can include other buildings on the same lot.
442 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jul 24, 2023 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPRX 2 SQUARE FEET IN THE 4th ROOM FROM EAST LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 24, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF A FREE STANDING RADIATOR AT PUBLIC HALL, 2nd STORY |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AND WEST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1A | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT THE WASTE LINE UNDER THE KITCHEN SINK IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION CLOSED | 1A | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT THE GAS RANGE IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION CLOSED | 1A | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION DISMISSED | 1A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILED FLOOR IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION DISMISSED | 1A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB FLOOR IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION CLOSED | 1A | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 19, 2023 | C | VIOLATION CLOSED | 1A | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN THE BATHTUB IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jun 21, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Jun 14, 2023 | A | NOT COMPLIED WITH | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| Jun 14, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| Jun 14, 2023 | A | NOT COMPLIED WITH | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Jun 14, 2023 | A | NOT COMPLIED WITH | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. AT PUBLIC HALL, 1st STORY |
| Jun 14, 2023 | A | NOT COMPLIED WITH | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| Jun 12, 2023 | C | VIOLATION CLOSED | 1F | § 27-2005 ADM CODE PROVIDE A PROPER SEAL AT ALL ACCESSIBLE OPENINGS ,SO AS TO PREVENT VANDALISM TO THE VACANT APARTMENT LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 9, 2023 | C | NOT COMPLIED WITH | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AT THE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Jun 9, 2023 | A | VIOLATION DISMISSED | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| Jun 9, 2023 | A | VIOLATION DISMISSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR DEFECTIVE AT PUBLIC HALL, 1st STORY |
| Jun 2, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ILLEGAL WIRE TAPPING AT THE CEILING LIGHT AT PUBLIC HALL, 2nd STORY |
| Jun 2, 2023 | C | VIOLATION WILL BE REINSPECTED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ILLEGAL WIRE TAPPING AT THE BREAKER BOX AND ELECTRIC METERS AT BASEMENT |
| Jun 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ILLEGAL WIRE TAPPING AT THE GAS METERS AT BASEMENT |
| May 17, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT THE BOILER ROOM AT BASEMENT |
| Apr 12, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT THE ENTRANCE TO THE BASEMENT AT BASEMENT |
| Apr 12, 2023 | C | VIOLATION WILL BE REINSPECTED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC WIRES AT THE CEILING AT BASEMENT |
| Apr 12, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RATED MATERIAL AT THE CEILING AT BASEMENT |
| Mar 27, 2023 | A | NOT COMPLIED WITH | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Mar 16, 2023 | C | VIOLATION WILL BE REINSPECTED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AT VESTIBULE AT PUBLIC HALL, 1st STORY |
| Mar 16, 2023 | C | NOT COMPLIED WITH | Not available | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE DOOR TO THE BUILDING AT PUBLIC HALL, 1st STORY |
| Mar 16, 2023 | A | NOT COMPLIED WITH | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT CELLAR |
| Mar 16, 2023 | B | VIOLATION CLOSED | Not available | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE STAGNANT WATER AT CELLAR AT CELLAR |
| Mar 16, 2023 | C | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION STEAM PIPE AT CEILING AT CELLAR |
| Mar 16, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT CELLAR |
| Mar 13, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRIC EXTENTION CORDS EXTENDED FROM APARTMENT 2 R BEING USED TO PRIVIDE LIGHTING AT THE IST STORY PUBLIC HALL CEILING AT PUBLIC HALL, 2nd STORY |
| Mar 13, 2023 | C | NOT COMPLIED WITH | Not available | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT PUBLIC HALL, 1st STORY |
| Mar 13, 2023 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ...LOCKED BASEMENT DOOR AT PUBLIC HALL, 1st STORY |
| Mar 13, 2023 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 2F | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXTENSION CORD TAPPED INTO CEILING FIXTURE RUN INTO APT 2R AT PUBLIC HALL, 2nd STORY |
| Mar 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT PUBLIC HALL, 2nd STORY |
| Mar 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT VESTIBULE NORTH WALL AT PUBLIC HALL, 1st STORY |
| Mar 2, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT VESTIBULE NORTH WALL AT PUBLIC HALL, 1st STORY |
| Feb 8, 2023 | A | NOT COMPLIED WITH | Not available | §27-2153 ADM CODE POST AND MAINTAIN A NOTICE, WRITTEN IN ENGLISH AND IN SPANISH, ON THE BUILDING ENTRANCE DOOR OR OTHER CONSPICUOUS LOCATION IN THE BUILDING COMMON AREA, STATING THAT: (1) THE BUILDING IS IN THE ALTERNATIVE ENFORCEMENT PROGRAM, (2) THAT OCCUPANTS MAY CALL 311 OR THE AEP AT 212-863-8262 TO REPORT HOUSING MAINTENANCE COMPLAINTS, (3) THE NAME, TELEPHONE, AND ADDRESS OF THE OWNER, AND, (4) THE IDENTITY OF ANY FINANCIAL INSTITUTION THAT HOLDS A MORTGAGE ON THE PROPERTY. POST AT PUBLIC HALL, 1st STORY |
| Feb 8, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC WIRES AT THE CEILING AT PUBLIC HALL, 1st STORY |
| Feb 8, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILED FLOOR AT PUBLIC HALL, 1st STORY |