Brooklyn Sunset Park (Central)
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
5 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Oct 24, 2022 | V-DOB VIOLATION - ACTIVE | COMPBLD-STRUCTURALLY COMPROMISED BUILDING NONE | FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG. |
| Jun 27, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EWO-ON 6/26/22 A FIRE OCCURD.EXP1 ROOF CORNICE &BRICK PARAPT WAS DMGD AND PARTIALLY COLLAPSD,& INADEQUATELY BRACED.EXP1 CORNICE/PARAPET AT RISK OF FURTHER COLLAPSE OWNER RETAIN NYSPE & GC REG W/DOB-IMMED PARTLY DEMO/BRACE HAZARDOUS CONDTNS @EXP1 W/TEMP STABILIZATN.FILE W/I 2DAYS |
| Jun 27, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM-ON 6/26/22 A FIRE OCCURRED.1FL INTERIOR FRAMING FIRE DMGD.APPRX FRONT 10FT ON 2FL JOIST FIRE DMGD.CORNICE PARTLY BURND COLLPSDALONG EXP1 @1/2 CORNER,W/BRICK PARAPET DMGD.ROOF OPEN DUE TO FIRE CUTS OWNR RTAIN NYSPE TO EVALU ENTIRE BLDG &PREPARE/FILE DWGS W/ DOB BY 8/1/22.OBTAIN PERMITS AND SIGN OFF BY 9/2/2022 |
| Jun 27, 2022 | V-DOB VIOLATION - ACTIVE | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | INSTALL 30' OF SIDEWALK SHED AT EXPOSURE#1 TO INCLUDE 5' OVERHANG ON EACH END TO PROTECT ADJACENT PROPERTIES AND TO SAFEGUARD THE PUBLIC AND PROPERTY. ALSO WILL REQUIRE DEBRIS REMOVAL |
| Jun 26, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | DUE TO FIRE STRUCTURE IS RENDERED NON-COMPLIANT. DAMAGE OBSERVED TO HAVE BEEN CAUSED BY FIRE WITH EXTENSIVE CHARRING TO STRUCTURAL MEMBERS THROUGHOUT, ROOF OPEN AND SMOKE AND WATER DAMAGE. VACATE FORTHWITH. |