| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Oct 28, 2019 | C | VIOLATION CLOSED | 8A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEIING IN THE BATHROOM LOCATED AT APT 8A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 28, 2019 | A | VIOLATION CLOSED | 15B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 7 SQ FT CEILING IN THE BATHROOM LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 28, 2019 | B | VIOLATION CLOSED | 15B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, EAST WALL IN THE BATHROOM LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 28, 2019 | B | VIOLATION WILL BE REINSPECTED | 15B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 28, 2019 | B | VIOLATION CLOSED | 15B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 28, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 15B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH WALL IN THE KITCHEN LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 28, 2019 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 15B | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 15B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 26, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BULKHEAD LEADING TO ROOF , SECTION ''WEST'' |
| Oct 26, 2019 | B | VIOLATION CLOSED | 12A | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE (OUT DATED) IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| Oct 26, 2019 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 12A | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| Oct 26, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 12A | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE (OUT DATED) IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| Oct 26, 2019 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 12A | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 12A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| Oct 26, 2019 | B | VIOLATION CLOSED | A10 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE (OUT DATED) IN THE ENTIRE APARTMENT LOCATED AT APT A10, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' |
| Oct 26, 2019 | B | VIOLATION CLOSED | A10 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE (OUT DATED) IN THE ENTIRE APARTMENT LOCATED AT APT A10, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' |
| Oct 26, 2019 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | A10 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT A10, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' |
| Oct 23, 2019 | C | VIOLATION CLOSED | 8A | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | A | VIOLATION CLOSED | 8A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM NORTH, THE 4th ROOM FROM NORTH AT EAST, THE 4th ROOM FROM NORTH AT WEST, THE KITCHEN , THE PRIVATE HALLWAY , THE BATHROOM LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, EAST WALL, NORTH WALL IN THE BATHROOM LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | A | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE FOYER LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL, SOUTH WALL, EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, SOUTH WALL, CEILING, WEST WALL IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL, NORTH WALL, CEILING IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 23, 2019 | B | VIOLATION CLOSED | 8A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL, EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 28, 2019 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOORS LOCKED AT YARD AT NORTH |
| Jul 28, 2019 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM INCORRECT INFORMATION AT NOTICE AT PUBLIC HALL, 1st STORY |
| Jul 28, 2019 | C | VIOLATION CLOSED | A1 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 4; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jul 28, 2019 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | A1 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jul 28, 2019 | C | VIOLATION CLOSED | A1 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jul 18, 2019 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT BOILER ROOM DOOR AT BASEMENT |
| Jul 18, 2019 | C | VIOLATION CLOSED | 1A | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| May 23, 2019 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY |
| May 23, 2019 | B | NOT COMPLIED WITH | A11 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO ROOM WITH FIRE ESCAPE WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| May 23, 2019 | B | VIOLATION CLOSED | A11 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| May 23, 2019 | B | VIOLATION CLOSED | A11 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| May 23, 2019 | B | VIOLATION CLOSED | A11 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| Mar 23, 2019 | B | VIOLATION CLOSED | B19 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B19, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 19, 2019 | C | DEFECT LETTER ISSUED | A11 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX.13 SQ.FT. IN THE BATHROOM LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 12969223 ISSUED 19-MAR-19 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE ''27-2017.3a(5)(a) or (b). |
| Mar 19, 2019 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK VESTIBULE DOOR AT PUBLIC HALL, 1st STORY |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX.13 SQ.FT. IN THE BATHROOM LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT FAUCET IN THE KITCHEN LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CABINETS NORTH WALL IN THE KITCHEN LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 19, 2019 | B | VIOLATION CLOSED | A11 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT A11, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Feb 27, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FOOD TRAY AND BOTTLES ON 2ND STORY BALCONY AT FRONT OF BUILDING EAST STACK AT FIRE ESCAPE |
| Feb 27, 2019 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL IN THE BULKHEAD LEADING TO ROOF AT PUBLIC HALL, 4th STORY |
| Feb 27, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL IN THE BULKHEAD LEADING TO ROOF AT PUBLIC HALL, 4th STORY |
| Feb 27, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BULKHEAD LEADING TO ROOF AT PUBLIC HALL, 4th STORY |