Brooklyn Downtown Brooklyn-DUMBO-Boerum Hill
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
21 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Feb 7, 2024 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 21, 2022 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021 |
| Mar 17, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 22, 2021 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | ADDITIONAL INFORMATION: ON 12/28/2020 DOB ORDERED THE GLASS CURTAIN WALL FACADES TO BE IMMED EVALUATED AND MADE SAFE. AS OF 1/22/2021 COMPLETE DOCUMENTATION FOR THE 100% HANDS ON INSPECTION AND ALL REQ'D DWGS/REPORTS HAVE NOT BEEN SUBMITTED. REMEDY: BY CLOSE OF BUSINESS 02/05/2021 SUBMIT ALL REPAIR DWGS ALLOWING REPAIRS TO BE MADE |
| Dec 28, 2020 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | AS PER INCIDENT #37750: BROKEN AND DISLODGED WINDOWS ON EXP #3 REMEDY: OWNER TO RETAIN A NYS LIC PROFESSIONAL TO PERFORM A 100% HANDS IN INSPECTION OF ALL WINDOWS AND PROVIDE THE DEPT OF BUILDINGS FACADE UNIT A ENGINEER'S REPORT AND PROPOSAL BY 1-28-21 |
| Dec 28, 2020 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | AS PER INCIDENT #37750: BROKEN AND DISLODGED WINDOWS ON EXP |
| Dec 25, 2020 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | AT TIME OF INSPECTION OBSERVED SEVERAL WINDOWES THROUGHOUT NEW BUILDIN G THAT HAVE SPRUNG OPEN FROM HIGH WINDS. CAUSING DANGER TO WINDOW GUIDES AND AFFECTING TRACKS ON SEVERAL WINDOWS THROUGHOUT BUILDING |
| Mar 31, 2020 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK. THE 44 STORY CONCRET CIP STRUCTURE WAS OBSERVED TO HAVE CRACKING,SPALLE CONCRETE AND BUCKLED ENFORCEMENT ON MULTIPLE INTERIOR COLUMNS WITH VARYIM |
| Dec 13, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | ADD INFO:NB#321185828-STRCT CRACKS,BUCKLE REBAR,SPALLS CONCR COLUMNS, DISCOLORED CONCR & SLABS-CRACKS MULTP FLRS.OWNR RETAIN 3RD PARTY ENGR TO PEER-REVIEW INVESTG PROCEDURES PROPOSED BY EOR,RESULTS& REPAIRS, ANALY&DESGN.PROVIDE NAMES OF 3 FIRMS BY 12/20/2019.PEER RVW TO START ONCE ENGR ACCEPTED BY DOB NO LATER THAN 12/27/2019 |
| Dec 13, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | ADD INFO:NB#321185828-STRCT CRACKS,BUCKLE REBAR,SPALLS CONCR COLUMNS, DISCOLORED CONCR & SLABS-CRACKS MULTP FLRS.OWNR RETAIN 3RD PARTY ENGR TO CONDUCT FORENSIC STRCTURAL ENGR EVAL OF BLDG TO DETERM CAUSE OF DMG PROVIDE REPORT TO DOB W/ CAUSES BY 2/14/2020.FORENSIC EVAL TO START ONCE ENGR ACCEPTED BY DOB NO LATER THAN 12/27/2019 |
| Dec 10, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | ADDITIONAL INFORMATION:NB# 321185828,44 STORY CONCRETE CAST IN PLACE STRUCTURE WITH STRUCTURAL CRACKS,BUCKLED REBAR AND SPALLED CONCRETE COLUMNS & SLABS WITH CRACKS ON MULTI FLOORS,AS OBSERVED ON DEC 5,2019 EOR REQ TO CONDUCT WKLY BLDG WALK THRU.PROVIDE S/S WKLY INSP REPT TIL REPRS CMPL AND SIGNED OFF.PROVIDE S/S PLAN.REPORT DEADLINE 12/24/19 |
| Dec 5, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMERG WORK:AS OBS.DURING AN INSP ON 12/5/19 MULTI CONCRETE COLUMNS ON MULTI FL LEVELS EXHIBITED CRACK,EXPOSED REBAR,DISCOLORATION.21ST FL EXHIBITING SEVERE CRACK,EXPOSED REBAR&BUCKLING.FEW CRACKS ON UNDERSIDE OF CONCRETE SLABS.STOP ALL WRK EXCEPT EMERG SHORING&SAFETY WORK.OWNER IMMED SHORE BLDG UNDR SUPV PE.TR1 REPTS CONC.TR2 COMPRESS RESULTS S/S |
| May 2, 2019 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Apr 21, 2018 | VP*-VIOLATION UNSERVED ECB- DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jan 25, 2018 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Feb 9, 2008 | VP*-VIOLATION UNSERVED ECB- DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| May 8, 2007 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 10, 1997 | VP*-VIOLATION UNSERVED ECB- DISMISSED | Z-ZONING NONE | Z-ZONING NONE |
| Apr 28, 1992 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Dec 9, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 50-PROVIDE ACCESS FOR INPECTION OF SAID ELEVATOR |
| Aug 30, 1988 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | (51) INSTALL SIGN INDICATING LOCATION OF EMERGENCY KEY FOR SHUTTER (52) DO NOT BLOCK AREA FOR EMERGENCY KEY TO SHUTTER |