Brooklyn East Williamsburg
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
12 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Aug 27, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Aug 27, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Aug 22, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 7, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 7, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 7, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 7, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 7, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 30, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | 517 STAGG ST:1 STRY,OCCUPIED WAREHOUSE W/WOOD BOWSTRINGTRUSS ROOF OWNER TO ENGAGE NYS LIC PE EXPRNC'D/WOOD TRUSSES TO PROBE& EVALUATE STRUCTR'L SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS,CALCULATION PROBES,ETC.& SUBMIT A REPORT.EACH TRUSS & BEARINGS TO BE SHORED.ANY STRUCT DEFICIENCIES SHORED.REPAIR DRWGS.FILED W/DOB WITHIN 45 DAYS VIO |
| Sep 24, 2015 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | 1 STORY INDUSTRIAL BLDG W/A WOOD BOWSTRING TRUSS ROOF.REMEDY:W/IN 60 DAYS OF DATE OF VIO OWNER TO ENGAGE A NYS LIC PE EXP'D W/WOOD TRUSSES TO PROBE & EVAL SRUCTUAL SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS CALCULATIONS PROBES ETC AND SUBMIT A REPORT ACCEPTABLE T/ THE DEPT REPAIR DRWGS T/BE FILED W/IN 45 DAYS AFTER THE INSPECTION |
| Oct 17, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO CMPLY W/A COMMS ORD. THE BLDG IS A WRHSE TYPE STRUC W/A WOO D BOWSTRING TRUSS ROOF. THE DEPT SERV YOU W/A CURABLE COMMS ORD (NOTIC E OF VIO) ON 5/5/14 TO PRODUCE AN ENGINEERS REPORT ON YOUR BLDG. NO EN GINEERS REPORT HAS BEEN RECEIVED. REMEDY: COMPLY WITH THE COMMISSIONER S ORDER |
| May 5, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | 517 STAGG ST:1 STRY,OCCP'D INDSTR'L/MANU.STRUCTURE/WOOD BOWSTRINGTRUSS ROOF.WITHIN 60DAYS OF VIO,OWNER TO ENGAGE NYS LIC PE EXPRNC'D/WOODTRUS TO PROBE&EVALUATE STRUCTR'L SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS,CALCULATIONS,PROBES,ETC. EA.TRUSS&BEARINGS EVAL'D. ANY STRUCTURAL DEFICIENCIES SHORED.REPAIR DRWGS.FILED WITHIN 45 DAYS/VIOLN |