Brooklyn Gravesend (East)-Homecrest
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
10 records
| Date | Status | Type | Summary |
|---|---|---|---|
| May 20, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM:DUE TO VEHICULAR IMPACT@THE BLDG ON 5/6/19 FRNT OF BLDG HAS BEEN PARTIALLY DEMOLISHED FROM GRADE TO ROOF.REMAIN OF THE BLDG HAS BEEN SHORED/BRACED &IS CURRENTLY OPEN TO WEATHER DETERIOR.OWN ENGAGE NYSPE& ENDORSED CONTR TO EVALUATE THE BLDG&REPR/DEMO THE PREMISE U/PRMT.PRMT TO BE OBT N/L/THAN 6/21/19.PRMT TO BE SIGNED OFF N/L/THAN 12/27/19 |
| May 20, 2019 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMG WRK ORDER:DUE TO VEHICULAR IMPACT@BLDG ON 5/16/19 BLDG HAS PARTY/W SHARED W/494 AVE P.STRUCT DMG WALL PRESENTS DIAG/VERTICAL CRACKS FROM 1TO2FL @FRNT PREMISE BLDG HAS BEEN PART DEMO FROM GRD TO ROOF REMAIND OF BLDG STRUCT COMPR IMM ENGAGE PE BRACE /SHORE&WATER PROOF REMAIN OF BLDG&REPR PARTY/W WRK CONTIN SUPV BY PE FILE W/IN 2 BUSS DAYS COMMENCE |
| May 7, 2019 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMG WRK:BLDG SUSTAINED VEHICLE IMPACT&PART COLLAP ON 5/6/19 APPROX 50% OF ROOF&2FL COLLAP ONTO 1FL ENTIRE EXP1 WALL&APPROX 50% OF EXP2 WALL PART COLLAP REMAINING BLDG UNSTAB&AT RISK OF COLLAP OWN IMM INST T/B/F & FULLY DEMO BLDG UNDER CONTINUOUS SUPERVISION PROVIDE MEANS&METHODS START WORK N/L/THAN 5/7/19 FILE PERMIT WITHIN 2 DAYS OF WORK START |
| Mar 1, 2013 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT |
| Apr 6, 2011 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Feb 7, 2000 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 16, 1993 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |