Apr 5, 2023 V*-DOB VIOLATION - DISMISSED LANDMK-LANDMARK NONE LANDMK-LANDMARK NONE
Mar 16, 2023 V*-DOB VIOLATION - DISMISSED EGNCY-EMERGENCY NONE DEMOLISH PARTIALLY COLLAPSED REAR WALL,PARTIALLY DEMOLISH & REBUILD IN KIND DETERIORATED,SAGGING & PARTIALLY COLLAPSED FLOOR+ROOF FRAMING(WIN THIN ~10 OF REAR)IN ORDER TO PREVENT DESTABILIZATION OF EXP#2 & #4 PAR TY WALLS AS WELL AS SEMI-DETACHED BLDG AT EXP#2,ENCLOSE BLDG ENVELOPE FRM ELEMENTS WFRAMED WEATHERPROOFING WALL ENSURING PROPER DRAINAGEROOF
Dec 19, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #121522FEU30201IK PER ORDER EMERGENCY WORK WAS TO BEGIN ON 12/21/2022.AS OF 1/4/2023 NO WORK AT SITE HAD COMMENCED.COMPLY WITH COMMISSIONER'S ORDER #121522FEU30201IK
Dec 15, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMER WRK.LFT&RGHT LOAD BEARNG WALLS PRTY WALLS.AT REAR OFBLDG,12"THICK BRICK WALL AT REAR SHEDDING BRCKS FRM PRTLLY CLLPSD@SPANDRELS AT FLS 1,2,3,LINTLS DFORMD & SPALLED,MORTAR ERRODED.COMPLY W/COMMISSIONER'S ORDER #121522FEU30201IK
Dec 15, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMER WRK.LFT&RIGHT LOAD BEARNG WALLS PRTY WALLS.AT REAR OF BLDG, 12" THICK BRCK WALL AT REAR SHEDDNG BRCKS FRM PRTLLY CLLPSD@SPANDRELS AT FLS 1,2,3,LINTELS DFORMD & SPALLED, MORTAR ERRODED.COMPLY WITH ORDER #121522FEU3020IK
Dec 15, 2022 V-DOB VIOLATION - ACTIVE IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL ERECT APPROXIMATELY 30 LINEAR FEET OF SIDEWALK SHED AT EXPOSURE#3 WITH OVER HANG ON BOTH SIDES
Dec 15, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMER WRK.LFT&RGHT LOAD BEARNG WALLS PRTY WALLS.AT REAR OF BLDG, 12"IN THICK BRCK WALL AT REAR SHEDDING BRCKS FRM PRTLLY CLLPSD @SPANDRELS AT FLS 1,2,3 LINTLS DFORMD & SPALLEDM MORTAR ERRODED.OWNR TO IMMED RETAIN NYS-LICENSED PE&DOB REG'D CNTRCTR TO 1.PRTLLY DEMO REAR WALL, REPAIR/ REPLACE DMGD & FAILD JOISTS
Dec 14, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSP. OBSERVED AT EXPOSURE #3 EXTERIOR MASONRY WALL IN COMPLETE DISREPAIR WHERE WALL IS LEANING/BULGING MISSING/LOOSE MORTAR AND BRICK WORK, EXPOSING INTERIOR TO ELEMENTS FURTHERING DETERIORATION OF STRUCTURE. WALL IN DANGER OF COLLAPSING INTO REAR YARDS TO INCLUDE
Dec 14, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED EXPOSURE #3 EXTERIOR MASONRY WALL IN COMPLETE DISREPAIR WHERE WALL IS LEANING/BULGING OUTWARD, MASONRY MISSING MORTAR & BRICK WORK. WINDOWS MISSING EXPOSING INTERIOR TO ELEMENTS FURTHERING DETERIORATION OF STRUCTURE WOOD MEMBERS. EXTERIOR HAS A POTENTIAL TO COLLAPSE.
Mar 8, 2017 V-DOB VIOLATION - ACTIVE LANDMK-LANDMARK NONE LANDMK-LANDMARK NONE
Mar 8, 2017 V-DOB VIOLATION - ACTIVE LANDMK-LANDMARK NONE LANDMK-LANDMARK NONE