Date Status Type Summary
Aug 31, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTC W/COMMISSIONER'S ORDER CONTROL#370544 VIO#072226PI30201SB DATED 07/22/2026 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 08/24/2026. AS OF 08/31/2026 THE REQ'D CAP WAS NOT REC'D. IMMED COMPLY WITH COMMISSIONER'S ORDER #072226PI30201SB
Aug 31, 2026 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTC W/COMMISSIONER'S ORDER CONTROL#370544 VIO#072226PI30201SB DATED 07/22/2026 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 08/24/2026. AS OF 08/31/2026 THE REQ'D CAP WAS NOT REC'D. IMMED COMPLY WITH COMMISSIONER'S ORDER #072226PI30201SB
Jul 27, 2026 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL AT EXPOSURE 1, APPROX. 50 LINEAR FT OF SIDEWALK SHED SHALL BE ERECTED ALONG THE FULL WIDTH OF THE FACADE, WITH AN EXTENSION OF 5 LINEAR FT TOWARD 421 GRAND AVE. ADDITIONALLY, PROVIDE CANTILEVER OF 5 LINEAR FT ALONG EXP 2 OF 423 GRAND AVE STARTING FROM EXP 1/2 CORNER. TOTAL OF 60 LINEAR FT OF SIDEWALK SHED
Jul 22, 2026 V-DOB VIOLATION - ACTIVE IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL REMEDY-AT EXPOSURE 1, APPROX. 50 LINEAR FEET OF SIDEWALK SHED BE ERECTED ALONG THE FULL WIDTH OF THE FACADE, WITH AN EXTENSION OF 5 LINEAR FT TOWARD 421 GRAND AVENUE. ADDITIONALLY, PROVIDE CANTILEVER OF 5 LINEAR FT ALONG EXP 2 OF 423 GRAND AV STARTING FROM EXP 1/2 CORNER TOTAL OF 60 LINEAR FT OF SIDEWALK SHED
Jul 22, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL CORRECTIVE ACTION PLN REQ'D-OBSVD @ EXP1 BRICK MASONRY STEP CRACK W/ CRACK EXTENDING INTO TOP FLOOR WATERTABLE CAUSING STONE TO BE SIGNIFICANTLY LOOSE AT THE EXP1/2 CORNDER NEAR PARAPET. OWNER TO IMMED RETAIN REG DESING PROF IN GOOD STANDING W/DOB&NYS TO EVAL ENTIRE BLDG & SUBMIT A CORRECTIVE ACTION PLAN BY 08/24/26
Jul 22, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD @ EXP1 LARGE BRICK MASONRY STEP CRACK THAT EEXTENDS INTO TOP FLOOR WATERTABLD CAUSING STONE TO BE LOOSE AT EXP1/2 PARAPET CORNER,@ EXP2 OBSVD MISSING MORTAR & LOOSE BRICKS AT PARAPET.AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D START 2024.SUBMIT ANNUAL PARAPET OBSERVATION REPORT FOR 2025 NO LATER 8/5/26
Dec 1, 2024 V-DOB VIOLATION - ACTIVE EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
May 2, 2019 V*-DOB VIOLATION - DISMISSED BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 2, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 18, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 4, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Feb 7, 2000 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 16, 1999 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
May 4, 1998 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 23, 1998 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Sep 16, 1997 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Feb 10, 1997 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jun 1, 1994 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Aug 16, 1993 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jun 1, 1993 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED