| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jul 27, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1AA | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE IN THE ENTRANCE LOCATED AT APT 1AA, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 27, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1AA | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1AA, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 27, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1AA | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1AA, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 27, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1AA | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1AA, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 27, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 1AA | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 1AA, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 26, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO NORTH FIRE STAIRS AT PUBLIC HALL, 1st STORY |
| Jul 26, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROPLADDER IN DOWN POSITION AT 1ST STACK FROM EAST AT NORTH AT FIRE ESCAPE |
| Jul 10, 2024 | C | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER IN DOWN POSITION, STACK AT NORTH AT FIRE ESCAPE |
| Jul 8, 2024 | B | NOT COMPLIED WITH | 4C | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 17103024 ISSUED 08-JUL-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Jul 8, 2024 | B | DEFECT LETTER ISSUED | 5J | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL LESS THAN 10 SQ. FT IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH ORIGINAL VIOLATION 17102557 ISSUED 08-JUL-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Jul 8, 2024 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE PRIVATE HALLWAY , THE FOYER , THE BATHROOM , THE 2nd ROOM FROM NORTH AT WEST, THE KITCHEN , THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE EXIT DOOR AT SOUTH AT PUBLIC HALL, 1st STORY |
| Jul 8, 2024 | C | VIOLATION CLOSED | 4C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER WINDOW FRAME AT WINDOW RECESS AT SOUTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | A | VIOLATION CLOSED | 4C | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS FRONT OF BUILDING AT EAST AT FIRE ESCAPE |
| Jul 8, 2024 | B | VIOLATION CLOSED | 5J | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | B | NOT COMPLIED WITH | 5J | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | A | NOT COMPLIED WITH | 5J | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILINGS AND ALL WALLS. IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | B | VIOLATION CLOSED | 5J | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | B | VIOLATION CLOSED | 5J | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | A | VIOLATION CLOSED | 5J | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL LESS THAN 10 SQ. FT IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 8, 2024 | B | VIOLATION CLOSED | 5J | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| Jul 7, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 6th STORY |
| Jul 7, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER AT CEILING AND SOUTH WALL AT PUBLIC HALL, 6th STORY |
| Jul 7, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO NORTH FIRE STAIRS AT BASEMENT. AT PUBLIC HALL |
| Jul 7, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER IN DOWN POSITION AT 1ST STACK FROM NORTH AT WEST AT FIRE ESCAPE |
| Jul 7, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER IN DOWN POSITION AT 1ST STACK FROM EAST AT NORTH AT FIRE ESCAPE |
| Jul 7, 2024 | A | VIOLATION CLOSED | Not available | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT 2ND STACK FROM EAST AT NORTH AT FIRE ESCAPE |
| Jun 18, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE |
| Jun 18, 2024 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT BUILDING FRONT AT 1st FIRE ESCAPE FROM EAST |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL APPROX 3 SQ FT IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17051524 ISSUED 16-JUN-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | A | VIOLATION CLOSED | 3J | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL APPROX 3 SQ FT IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Jun 16, 2024 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3J | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE, SECOND WINDOW FROM NORTH AT EAST LOWER SASH IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| May 28, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING BRICK AT (WEST 2) FIRE DOOR AT PUBLIC HALL, 1st STORY |
| May 28, 2024 | C | NOT COMPLIED WITH | 5DD | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER WINDOW SASH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5DD, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| May 28, 2024 | B | NOT COMPLIED WITH | 5DD | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5DD, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |