Brooklyn Windsor Terrace-South Slope
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
12 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Mar 13, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN.AT TIME OF INSPECTION,OBSRVD BLDG IN A STATE OF DISREPAIR W/EVIDENCE OF SIGNIFICANT&CONTINUED SETTLEMNT OF THE BLDG OBSRVD BLDG LEANING TOWARDS EXP 1-4 CRNR W/STEP CRCKS,LOOSE/UNSPR COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #123024CFEU30703AK (CONTROL 3341800) IMMEDIATELY |
| Dec 31, 2024 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | ERECT APPROXIMATELY 30 L.F. OF SIDEWALK SHED ALONG EXPOSURE 1 |
| Dec 30, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN.AT TIME OF INSPECTION,OBSRVD BLDG IN A STATE OF DISREPAIR W/EVIDENCE OF SIGNIFICNT&CONTINUED SETTLEMNT OF THE BLDG OBSRVD BLDG LEANING TOWARDS EXP 1-4 CRNR W/STEP CRCKS,LOOSE/UNSPPRTD MASONRY/STONE.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTRTO EVAL THE ENT BLDG& PERM RPAIR PRMT.FILE FOR RPAIRS BY 5/3/23.SGN OFF RPAIRS BY 6/3/25 |
| Nov 15, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | ENGINNERS REPORT REQUIRED FOR FACADE DUE TO 20 FEET VERTICAL CRACK , B RICK FACADE SEPARATION @ FRONT RIGHT AND DIAGONAL CARCK IN STUCCO |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 4, 1998 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 16, 1993 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 1, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |