Brooklyn Bedford-Stuyvesant (East)
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
6 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Sep 21, 2021 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 19, 2020 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 5, 2017 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | PRELIMINARY STRUCTURAL REVIEW REPORT, PREPARED BY GLEN LANGER, PE, CITED BOTH THE ORIGINAL STRUCTURAL DESIGN AND THE AS-BUILT STRUCTURE, ARE NOT CODE COMPLIANT FOR BOTH GRAVITY AND LATERAL SYSTEMS. THE RPRT CITES OVERALL CODE DEFICIENCIES; IT DOES NOT ADDRESS ALL CODE REQUIRED LATERAL LOADS AND IS DEEMED INCOMPLETE AND UNACCEPTED |
| Dec 16, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WTH COMMISSIONER'S ORDER #290749, REQUIRING OWNER TO START EMERGENCY WORK NO LATER THAN 12/5/16 |
| Dec 2, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | OWNER TO IMMEDIATELY INSTALL THE TEMPORARY BRACING SYSTEM TO LATERALLY SHORE THE BLDG. START WORK NO LATER THAN 12:00 PM 12/5/16. WORK TO BE PERFORMED UNDER PE SUPERVISION. FILE FOR PERMIT WITHIN 48 HOURS OF COMMENCING WORK. FAILURE TO COMPLY WILL RESULT IN CITY PERFORMING WORK |
| May 20, 2016 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN: SLAB CRACKS IN GIRDERS FROM 1ST FL TO ROOF; STEEL FILLER BEAMS SIGNIFICANTLY DEFLECTED AT EACH FLOOR PROVIDE TEMP SHORING FROM ROOF TO-SLAB-ON-GRADE. RETAIN SURVEY COMPANY TO PERFORM SURVEY AND SUBMIT REPORTS ON COLUMN PLUMBING & SLAB SAGGIN G DEFLECTIONS. WORK TO START IMMEDIATELY |