| Date | Status | Type | Summary |
|---|---|---|---|
| Jan 30, 2010 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BORO COMM'S 15 DAY LETTER REMEDY; STOP ALLWORK MAKE SITE SAFE |
| Dec 8, 2009 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Dec 10, 2008 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Apr 9, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jan 24, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED PLANS NOTED: 302321752 NB SOLDIER PILES OUT OF PLUMB PLAN VOID OF PILE PLACEMENT LOCATIONS INSTALLED LAGGING CONTRARY PILES UNDER SIZED TWISTED PILE BELOW GRADE APPROX 3'- 6' REAR THRU OUT REMEDY: STOP ALL WORK FORTHWITH CONTACT EXCAVATION AT 718 802-4594 WHEN REMEDY IS COMPLETED |
| Jan 24, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED PLANS NB#302321743 NOTED: SHORING BELOW HEIGHT REAR THRU-OUT SHORING UNDER SIZED AND VERING GRADE 3'-6' THRU OUT REMEDY: STOP ALL WORK EXCEPT TO REPAIR FENCE CONTACT EXCAVATION UNIT 718 802-4594 WHEN REMEDY COMPLETED ONLY |
| Jan 24, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO PLANS ACTIVE SITE JOB# 302321743 INSTALLED LAGGING NOT BETWEEN SOLDIER BEAM WEB PILES UNDER SIZE & TWISTED PLANS VOID OF PLACEMENT LOCATION APPROX 25% WORK SCOPE COMPLETED REMEDY: STOP ALL WORK EXCEPT TO MAKE SAFE CALL EXCAVATION 718 802-4594 |
| Jan 24, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO PLANS ACTIVE SITE UNDER JOB#302321761 NOTED: NON-CONFORMING ON SITE SHORING ERECTED SOLDIER BEAMS ARE OUT OF PLUMB/ TWISTED AT VARIOUS LOCATION SOLDIER BEAM ARE NOT ABOVE GROUND AND NO RAKERS ERECTED LAGGINGS ARE INSTALL BEHIND SOLDIER BEAM INSTEAD OF IN STALLING THEM IN BETWEEN WEB REMEDY: STOP ALL WORK EXCEPT TO MAKE SAFE |
| Jan 24, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO PLANS ACTIVE SITE UNDER JOB#302321547 NOTED: NON-CONFORMING WORK ON SITE SHORING ERECTED SOLDIER BEAMS ARE OUT OF PLUMB/TWISTED AT VARIOUS LOCATIONS SOLDIER BEAMS ARE NOT ABOVE GROUND AND NO RAKERS ERECTED LAGGINGS ARE NOT INSTALLED BETWEEN WEB AS PER PL ANS REMEDY: STOP ALL WORK EXCEPT TO MAKE SAFE ONLY 718 802-4594 |
| May 28, 1992 | VP*-VIOLATION UNSERVED ECB- DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Feb 6, 1991 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | ES-ELECTRIC SIGNS NONE | ES-ELECTRIC SIGNS NONE |