Brooklyn Brighton Beach
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-08669-0077), so they can include other buildings on the same lot.
187 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jan 8, 2025 | B | VIOLATION DISMISSED | 10B | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jan 8, 2025 | A | VIOLATION DISMISSED | 10B | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jan 8, 2025 | B | VIOLATION DISMISSED | 10B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE BATHROOM LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jan 8, 2025 | B | VIOLATION DISMISSED | 10B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Dec 31, 2024 | A | VIOLATION DISMISSED | 10B | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE BATHROOM LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Dec 31, 2024 | B | VIOLATION DISMISSED | 10B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 10B, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 6, 2024 | A | VIOLATION DISMISSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 3rd STORY, SECTION ''SOUTH'' |
| Jul 6, 2024 | A | VIOLATION DISMISSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 4th STORY, SECTION ''SOUTH'' |
| Jul 6, 2024 | B | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARTEN MATERIAL AT CEILING AT PUBLIC HALL, 4th STORY, SECTION ''SOUTH'' |
| Jul 6, 2024 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BOXES AND HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY, SECTION ''SOUTH'' |
| Jul 6, 2024 | A | VIOLATION DISMISSED | 8D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 5 SQFT OF MOLD AT CEILING IN THE BATHROOM LOCATED AT APT 8D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Jul 6, 2024 | B | VIOLATION DISMISSED | 8D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN WATERBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 8D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Jul 6, 2024 | C | VIOLATION DISMISSED | 8D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Jul 6, 2024 | A | VIOLATION DISMISSED | 8D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 3 SQFT OF MOLD AT CEILING IN THE KITCHEN LOCATED AT APT 8D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Jul 6, 2024 | A | VIOLATION DISMISSED | 8D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 8D, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Jul 1, 2024 | A | VIOLATION DISMISSED | Not available | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT SOUTH FIRE ESCAPE AT BUILDING FRONT |
| Mar 14, 2024 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Mar 14, 2024 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BABY CARRIAGES AT PUBLIC HALL, 1st STORY |
| Sep 4, 2021 | B | VIOLATION DISMISSED | 4D | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS PANE LOWER SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | B | VIOLATION DISMISSED | 4D | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE WINDOW LOWER AND UPPER SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | C | VIOLATION DISMISSED | 4D | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .... IN THE ENTRANCE LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | A | VIOLATION DISMISSED | 4D | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE AT ALL WALL TILES OVER BATHTUB AROUND IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | B | VIOLATION DISMISSED | 4D | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | B | VIOLATION DISMISSED | 4D | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | C | VIOLATION DISMISSED | 4D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 4, 2021 | B | VIOLATION DISMISSED | 4D | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jul 26, 2021 | B | VIOLATION DISMISSED | APT8C | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Jul 26, 2021 | B | VIOLATION DISMISSED | APT8C | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Jul 26, 2021 | C | VIOLATION DISMISSED | APT8C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 3; IN THE ENTIRE APARTMENT LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Jul 26, 2021 | B | VIOLATION DISMISSED | APT8C | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE COVER FOR ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Jul 26, 2021 | B | VIOLATION DISMISSED | APT8C | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Jul 26, 2021 | B | VIOLATION DISMISSED | APT8C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT APT8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Sep 15, 2020 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER PROTRUDING AT WINDOW SILL ON 2ND STORY BALCONY SOUTHWEST STACK, BUILDING FRONT AT FIRE ESCAPE |
| Sep 15, 2020 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER PROTRUDING AT WINDOW SILL ON 2ND AND 3RD STORY BALCONIES NORTHWEST STACK, BUILDING FRONT AT FIRE ESCAPE |
| Sep 15, 2020 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 2ND STORY BALCONY NORTHWEST STACK, BUILDING FRONT AT FIRE ESCAPE |
| Aug 24, 2020 | A | VIOLATION DISMISSED | 8C | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Aug 24, 2020 | A | VIOLATION DISMISSED | 8C | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE FOYER LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Aug 24, 2020 | C | VIOLATION CLOSED | 8C | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Aug 24, 2020 | C | VIOLATION CLOSED | 8C | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE FOYER LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Aug 24, 2020 | C | VIOLATION CLOSED | 8C | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH |
| Aug 6, 2020 | C | VIOLATION CLOSED | 8C | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Jun 16, 2020 | C | VIOLATION DISMISSED | 8C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT WITH EYE ARANGED TO BE PAD LOCKED INSTALED AT DOOR IN THE ENTRANCE LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Jun 16, 2020 | C | VIOLATION CLOSED | 8C | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Jun 16, 2020 | B | VIOLATION DISMISSED | 8C | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 4th ROOM FROM NORTH LOCATED AT APT 8C, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Oct 17, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION 2 RADIATORS AT EAST WALL AT LOBBY, 1st STORY |
| Oct 17, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR AT SOUTH WALL AT PUBLIC HALL, 1st STORY, SECTION AT NORTH |
| Oct 17, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR AT NORTH WALL AT PUBLIC HALL, 1st STORY, SECTION AT SOUTH |
| Oct 17, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. |
| Oct 17, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| Oct 17, 2018 | C | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCONECTED RADIATOR FREE STANDING AT PUBLIC HALL, 1st STORY, SECTION AT SOUTH |