Date Class Status Apartment Summary
Mar 20, 2023 B NOV SENT OUT Not available § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT CEILING AT VESTIBULE AT PUBLIC HALL, 1st STORY
Nov 10, 2022 I INFO NOV SENT OUT Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Feb 23, 2022 I INFO NOV SENT OUT Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Feb 23, 2022 A NOV SENT OUT Not available (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Jan 9, 2022 B NOV SENT OUT Not available § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK ON METAL GATE SOUTH YARD
Jan 9, 2022 C VIOLATION CLOSED Not available § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT PUBLIC HALL, 4th STORY
Jan 9, 2022 B NOV SENT OUT Not available § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIAL AT BULKHEAD STAIRS AT PUBLIC HALL, 4th STORY
Jan 9, 2022 A NOV SENT OUT Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT BULKHEAD CEILING AND ALL WALLS AT PUBLIC HALL, 4th STORY
Jan 9, 2022 B NOV SENT OUT Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT BULKHEAD CEILING AT PUBLIC HALL, 4th STORY
Jan 9, 2022 A NOV SENT OUT Not available § 27-2005 ADM CODE REFIT BULKHEAD DOOR AT PUBLIC HALL, 4th STORY
Nov 13, 2021 A NOV SENT OUT Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT BULKHEAD TO ROOF
Nov 13, 2021 B NOV SENT OUT Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE FIRE RETARDANT MATERIAL AT BULKHEAD TO ROOF
Nov 13, 2021 B NOV SENT OUT Not available § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT BULKHEAD TO ROOF
Apr 7, 2021 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Apr 7, 2021 A NOV SENT OUT Not available (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Jan 17, 2020 B NOV SENT OUT Not available § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER AT 3RD STORY BALCONY,WEST STACK
Oct 29, 2019 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Mar 2, 2019 C NOV SENT OUT B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOTWATER EXCEEDING THE MAXIUM TEMPERATURE OF 130 DEGREES AT HOT WATER FIXTURE AT SINK IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Oct 24, 2018 A NOV SENT OUT Not available § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Oct 24, 2018 B NOV SENT OUT B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT INSTALLED ON THE INTERIOR OF DOOR IN THE ENTRANCE LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Oct 24, 2018 C VIOLATION CLOSED B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE ALLOWABLE MAXIMUM TEMPERATURE OF130.F DEGREES ( FOUND 138.F ) AT HOT WATER FIXTURES, IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Oct 16, 2018 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Jul 17, 2018 B NOV SENT OUT Not available § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS OF INCANDESCENT LIGHT REQUIRED. AT FRONT AREAWAY
Jan 26, 2018 B NOV SENT OUT B2 § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Jan 26, 2018 A NOV SENT OUT B2 § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .... IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Nov 20, 2017 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Mar 20, 2017 B NOV SENT OUT B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT INSTALLED ON DOOR IN THE ENTRANCE LOCATED AT APT B5, 2nd STORY, APARTMENT AT NORTH
Mar 20, 2017 B NOV SENT OUT B5 § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING LIFT ON UPPER AND LOWER SASH AT WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2nd STORY, APARTMENT AT NORTH
Mar 17, 2017 B NOV SENT OUT 2B § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 2B, 2nd STORY, APARTMENT AT SOUTH
Mar 17, 2017 B NOV SENT OUT 2B § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 2B, 2nd STORY, APARTMENT AT SOUTH
Mar 17, 2017 C NOV SENT OUT Not available § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT BASEMENT
Mar 17, 2017 C NOV SENT OUT 2B § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, APARTMENT AT SOUTH
Mar 2, 2017 B NOV SENT OUT Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOCK AT APT D2 MAIL BOX DOOR AT PUBLIC HALL, 1st STORY
Feb 2, 2017 B NOV SENT OUT B6 § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE ... IN THE KITCHEN LOCATED AT APT B6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Feb 2, 2017 C VIOLATION CLOSED B6 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDS THE MAXIMUM OF 130 DEGREES, FOUND HOT WATER TO BE 148 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT B6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Dec 25, 2016 B NOV SENT OUT B5 § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE 4th ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 25, 2016 B NOV SENT OUT B5 § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE 3rd ROOM FROM EAST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 25, 2016 C VIOLATION CLOSED B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR SHUT- OFF VALVE IN THE KITCHEN LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 25, 2016 A NOV SENT OUT B5 § 27-2005 ADM CODE REFIT UPPER AND LOWER WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 25, 2016 B NOV SENT OUT B2 § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE UNDER SINK IN THE KITCHEN LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Dec 25, 2016 B NOV SENT OUT B2 § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Dec 25, 2016 B NOV SENT OUT B2 § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Dec 25, 2016 B NOV SENT OUT B2 § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Dec 25, 2016 A NOV SENT OUT B2 § 27-2005 ADM CODE REFIT UPPER AND LOWER WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
Dec 10, 2016 C VIOLATION CLOSED B5 § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM OF 130 DEGREES FOUND HOT WATER TO BE 138 DEGREES . IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Nov 24, 2016 B NOV SENT OUT B5 SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SLID BOLT WITH LOCKABLE HASP INSTALL AT DOOR. IN THE ENTRANCE LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Nov 24, 2016 B NOV SENT OUT B5 SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOUSE HOLD FURNITURE BLOCKING FIRE ESCAPE WINDOW. IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT B5, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Nov 4, 2016 I VIOLATION DISMISSED Not available §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
Oct 10, 2015 B NOV SENT OUT D5 SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Oct 10, 2015 B NOV SENT OUT D5 SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM WEST AT NORTH