NYC Building Report

Brooklyn East Flatbush-Erasmus

297 Lenox Road, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

29 records

Date Status Type Summary
May 15, 2024 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 18, 2021 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 18, 2021 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 6, 2021 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM BLDG SAFE CONDN:ADJ EXP4 VACANT LOT.LOT LINE WALL @EXP1/4 QUADRANT OF BLDG SUFERD DMG DUE TO DIFFERNTL SETTLMNT.RPRD CRK SOG@FIRE PASSAGE WY@EXP4;SEPRTN 1FL FRMG FRM EXP4;CRKS-FACDE BRKS IN WALLS ABV.STRL STL BRCE INSTL@ALL FLS.OWNR RETN NYSPE&DOB REG CONTR-EVAL FDN+SUPER STRCT+ PERFM RPRS UNDR PRMT.FIL APPL BY 9/7/21.BEGN BY 10/7/21.CMPLT BY4/7/22
Dec 12, 2018 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Nov 24, 2018 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Aug 14, 2018 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN SAFE COND AFTER INCIDENT OCCURRED ON 1/25/17.BLDG HAS SIGNIFICANT STRL CRACK ON FOUND LINE A ALONG EXCAV SITE 309 LENOX RD HORIZON CRACKS OBSERVE IN APTS ON LINE A.REMEDY:OWN ENGAGE ENG EVAL FOUND&LINE A APTS&OBT PERM FOR RPRS NO LATER 9/17/18.WRK UND PERM TO START NO LATER 10/17/18.PART VACATE APTS LINE A 1ST TO 6THFL
Nov 19, 2017 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jun 28, 2017 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 12, 2017 V*-DOB VIOLATION - DISMISSED EGNCY-EMERGENCY NONE FTM / STRAPS
Apr 7, 2017 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAIL TO COMPLY W/COMMISSIONER ORDER#334414 ISSUED 1/27/17 TO INSERT STRAPSS ALONG EXT WALLS W/CRACKS&ERECTION OF SCAFFOLDING TO CARRY OUT THIS WORK.NO SCAFFOLDING HAS BEEN INSTALLED OR STRAPS HAS BEEN INSERT AT ALL CRACKED WALLS AS OF 4/7/17.REMEDY:COMPLY WITH COMMISSIONER ORDER#334414 IMMED
Jan 27, 2017 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EMERG WORK.VERT CRACKS AT 297 LENOX RD VISIBLE SLONG "A" EXT WALL HORIZONTAL INTERIOR CRACKS OBSERVED AT ALL APTS LOCATED ON LINE"A".THE UNDERLYING SOIL UNDER LINE OF APTS IS AFFECTED BY EXCAVATION AT 309 LENOX RD. REMEDY:OWNER IMMED ENGAGE NYSPE ENGR&CONT'R TO INSERT STRAPS ALONG EXT WALLS W.CRACKS ERECT SCAFFOLD TO CARRY OUT THE WORK
Jan 27, 2017 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Jan 26, 2017 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FM BLDG IN SAFE COND.THERE ARE SIGNIFICANT STRL CRACKS ON FOUNDATION AT LINE "A" ALONG THE EXCAVATION SITE AT 309 LENOX RD.VERT CRACKS ARE VISIBLE ALONG LINE "A" WALL FROM GRADE TO ROOF.REMEDY:OWNER ENGAGE A LIC PE ENG'R EVAL FOUNDATION&LINE "A" APTS&PREP PLANS FOR PERM NO LATER THAN 2 MTHS.WORK START NO LATER THAN 3 MTHS
Dec 29, 2015 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Dec 7, 2014 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 19, 2013 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Sep 11, 2012 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 15, 2011 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Nov 17, 2010 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 31, 2009 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 10, 2008 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jun 1, 2007 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Dec 8, 2004 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Jun 17, 2003 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Apr 11, 2002 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED E-ELEVATOR ELEVATORREQUIRED
Mar 14, 2001 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED 3P3119
Feb 10, 1997 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
May 18, 1990 V*-DOB VIOLATION - Resolved E-ELEVATOR ELEVATORREQUIRED (74)REPLACE WORN CAR DOOR SADDLE (74A)PROVIDE LIGHT ON MOTOR ROOM (74B)PROVIDE COVER ON INTERLOCK