HPD violations

Housing Maintenance Code violations are filed by tax lot (BBL 3-01528-0057), so they can include other buildings on the same lot.

206 records

Date Class Status Apartment Summary
Jan 8, 2015 C VIOLATION CLOSED 1FL § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES THROUGHOUT THE KITCHEN AND BATHROOM IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Jan 8, 2015 C VIOLATION CLOSED 3FL § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
Jan 8, 2015 C VIOLATION CLOSED 2FL § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES THROUGHOUT THE BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Jan 8, 2015 C VIOLATION CLOSED 2FL § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES THROUGHOUT BATHROOM AND KITCHEN, IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Jan 8, 2015 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND SLATE SLAB TREADS, (9) TO REAR YARD FROM CELLAR, ADJACENT TO EAST WALL AT BOILER ROOM
Jan 8, 2015 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROVIDE SEAL FOR WINDOWS AT CELLAR REAR FOUNDATION WALL AT BOILER ROOM
Jan 8, 2015 C VIOLATION CLOSED Not available § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT HOT AND COLD WATER RISERS, CASCADING AT THE CEILING AT THE BOILER ROOM AT BOILER ROOM
Jan 5, 2015 C VIOLATION CLOSED Not available § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION LEAKING STEAM AND WATER AT RADIATOR CUPLING TO SHUT OFF VALVE, WEST WALL AT PUBLIC HALL
Dec 11, 2014 B VIOLATION CLOSED 1 § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CASINGS AND EXPOSED PLASTER BOARD AT DOOR FRAME, IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 11, 2014 C VIOLATION CLOSED 1 § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING GLASS AT LOWER SASH SOUTH EAST WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 11, 2014 C VIOLATION CLOSED 1 § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT TWO BOTTOM SASHES, 2 WINDOWS AT WEST WALL IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 11, 2014 B VIOLATION DISMISSED 1 § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD, REMOVE THE DOOR STOP TO COMPLETE THE ARCHWAY OPENING AT ROOM EAST 3 DOOR FRAME, ACCESSING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 11, 2014 B VIOLATION CLOSED 1 § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CASINGS AT INNER AND OUTER DOOR FRAME IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 11, 2014 B VIOLATION CLOSED 1 § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SOUTH DOOR FOR ENTRANCE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Dec 1, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT CEILING IN THE BOILER ROOM AT CELLAR
Dec 1, 2014 C VIOLATION CLOSED Not available § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT A DRESSER CUPPLING AT RETURN LINE OF THE HEATING SYSTEM AT BOILER ROOM AT CELLAR
Dec 1, 2014 C VIOLATION CLOSED Not available § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT PUBLIC HALL AND HEATING SYSTEM FROM THE PLP METER AT FRONT AT CELLAR
Dec 1, 2014 C VIOLATION CLOSED Not available § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF WIRE TAPPING AT ELECTRIC MAIN PANNEL SUPPLYING 2ND STY APT 2 FROM ANOTHER ELECTRIC SERVICE SOURCE, PANNEL AT FRONT AT CELLAR
Nov 24, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROVIDE A LUVER VENT AT THE NORTH WALL TO VENT TO THE EXTERIOR, AT CELLAR AT BOILER ROOM
Nov 24, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT CEILING AT BOILER ROOM
Nov 17, 2014 C VIOLATION CLOSED Not available § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION , LEAKING SECTIONS AT THE HEATING SYSTEM WETTING BURNER CHAMBER AT BOILER ROOM
Nov 17, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GAS BURNER CHAMBER ASSEMBLY DISMANTELED AT HEATING SYSTEM AT BOILER ROOM
Oct 30, 2014 C VIOLATION CLOSED Not available § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION , EROSION AND HEAVY RUST THROUGHOUT WATER CHAMBERS OF THE HEATING SYSTEM AT BOILER ROOM
Oct 20, 2014 B VIOLATION CLOSED Not available § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT STAIRS LEADING TO OPEN SPACE AT CELLAR
Oct 20, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC CEILING LIGHT FIXTURES THROUGHOUT AT CELLAR
Oct 20, 2014 C NOT COMPLIED WITH Not available § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOUBLE TRAP DOORS AT REAR YARD STAIRS AT CELLAR
Oct 20, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAIN CONTROL GAS VALVE AT HEATING SYSTEM , BOILER ROOM AT CELLAR
Oct 20, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC CONTROLS AT HEATING SYSTEM AT CELLAR
Oct 20, 2014 A VIOLATION CLOSED Not available § 27-2026 ADM CODE REMOVE DISUSED PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS , DISCONTINUED WASTE LINE AND WATER LINES THROUGHOUT CEILING AND WALLS AT CELLAR
Oct 20, 2014 C VIOLATION CLOSED Not available § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF HANGING LIVE BX WIRE AND JUNCTION BOXES THROUGHOUT CEILING AND WALLS AT CELLAR
Oct 9, 2014 C VIOLATION CLOSED 2FL § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE INSTALLED AT WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Oct 9, 2014 C VIOLATION CLOSED 2FL § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNKEYED PLASTER BOARD CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Oct 9, 2014 C VIOLATION CLOSED 2FL § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNKEYED PLASTER BOARD CEILING IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 B VIOLATION CLOSED Not available § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING THROUTHOUT CELLAR FROM ENTRANCE STAIRS TO BOILER ROOM AT CELLAR
Sep 2, 2014 C VIOLATION CLOSED Not available § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT ALL STORIES AND LANDINGS AT PUBLIC HALL STAIRS
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE SURFACES AT BATHTUB NORTH EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE PLASTER BOARD CEILING IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK COMING FROM ABOVE THE CEILING IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING GLASS AT UPPER SASH AT 1ST WINDOW FROM WEST AT NORTH IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING GLASS AT BOTTOM SASH, 2ND WINDOW FROM WEST AT NORTH IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 B VIOLATION CLOSED 1FL § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT UPPER AND LOWER SASHES AT (2) NORTH WINDOWS IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT UPPER AND LOWER SASHESW, AT 1ST WINDOW FROM EAST AT SOUTH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Sep 2, 2014 C VIOLATION CLOSED 1FL § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT BOTTOM SASH, 1ST WINDOW FROM EAST AT SOUTH, FACING STREET IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Aug 6, 2014 B VIOLATION CLOSED Not available § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING THROUGHOUT THE CELLAR CEILING AT CELLAR
Jul 30, 2014 C VIOLATION CLOSED Not available § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SCATTERED RUBBISH AND HOUSE HOLD ITEMS UNUSED THROUGHOUT PAVING AT CELLAR
Jul 30, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE RETARDENT METAL DOOR AT REAR ENTRANCE AT CELLAR
Jul 30, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE RETARDENT METAL DOOR AT ENTRANCE, UNDER STAIRS AT FRONT AREAWAY FOR ACCESS AT CELLAR
Jul 30, 2014 B VIOLATION CLOSED 3FL § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3FL, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Jul 16, 2014 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT PLASTER THROUGHOUT WALLS AND CEILING AT THE VESTIBULE AT PUBLIC HALL, 1st STORY
Jul 16, 2014 C VIOLATION CLOSED Not available § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK FROM ABOVE THE CEILING AT THE VESTIBULE AT PUBLIC HALL, 1st STORY