Brooklyn Williamsburg
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
6 records
| Date | Status | Type | Summary |
|---|---|---|---|
| May 22, 2010 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK,MAKE SITE SAFE,CONTACT THE DOB |
| Mar 6, 2010 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK,MAKE SITE SAFE,CONTACT THE DOB |
| Nov 20, 2008 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV ED AMENDMENTS IN THAT NEW METAL JOISTS ARE SISTERED TO EXISTING WOOD J OISTS AT CELLAR FOR SUPPORT OF FIRSTS FLOOR PLANS SHOW "EXISTING JOIST S - NO CHANGE REMEDY: AMEND PLANS TO SHOW ACCEPTABLE AS BUILD CONDITIONS |
| Oct 11, 2008 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | MISCELLANEOUS VIOLATIONS, FAILURE TO COMPLY WITH AN ORDER TO STOP WORK BY DOB FULL STOP WORK ORDER 051805C01AH02 ISSUED ON AUG 18, 2005 FOR REMOVING SUPPORT BEAMS & GUTTING ENTIRE BUILDING WITHOUT PERMITS AT TI ME OF INSPECTION OBSERVED MASONS LAYING BRICK AT 2ND FLOOR OF EXPOSURE #2 REMEDY: COMPLY WITH NOTICE OF VIOLATION STOP ALL WORK IMMEDIATELY |
| Oct 11, 2008 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO PROVIDE APPROVED PLANS ON SITE AT TIME OF INSPECTION CONTRA CTOR HAS EXCAVATED CELLAR, UNDERPINNED ADDED STRUCTURAL STEEL, JOIST R EPLACEMENT & STEEL STAIR INSTALLATION WITH NO APPROVED PLANS ON SITE REMEDY: STOP ALL WORK PROVIDE APPROVED PLANS |
| Apr 2, 2006 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK W/OUT PERMIT |