NYC Building Report

Brooklyn Ocean Hill

2188 Fulton Street, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

26 records

Date Status Type Summary
Nov 12, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOP UNDER PERMIT #B01025882-I1 ON 11/7/25. CONSTRUCTION SUPERINTENDENT WITHDRAWAL
Jun 30, 2023 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 14, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER-IMMED REPAIR PIPE SCAFFOLD AND VERTICAL NETTING AT EXP1 AND 2. MAKE SITE SAFE. REMEDY: COMPLY WITH NYC DOB CODE
Dec 9, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Sep 2, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Mar 4, 2020 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 26, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Dec 11, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Oct 17, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jul 24, 2019 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
May 17, 2019 V%-DOB VIOLATION UB-UNSAFE BUILDINGS NONE UB-UNSAFE BUILDINGS NONE
May 3, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:BLDG IN EXTREME STATE OF DISREPAIR.MISSING&LOOSE BRICKS&OPEN HOLES IN EXP1&2 WALLS.LINTELS MISSING@EXP3 WALL.OPEN HOLES FL JOIST ROTTED& PART COLLAP IN MULTI LOCAT@ALL FLRS&ROOF.SHARED REAR EXP4 CHIMNEY PART COLLAP.PE EVAL ENTIRE BLDG&DSGN REPRS&STBL.COMPL REPRS&STABL WRK UNDER PRMT.FILE 7/15/19 WRK ST 8/5/19 DONE 9/2/19 WRK COMPL & S/O 12/27/19
May 3, 2019 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL INSTALL APPROX.30 LINEAR FT OF SIDEWALK SHED AT FRONT(EXP#1)OF COVER THE ENTIRE FRONT YARD &SIDEWALK THE SIDEWALK SHED SHALL EXTEND 5LINEAR FEET TO PROVIDE FRONT YARD PROTECTION AT THE ADJACENT PROPERTY 2186 FULTON STREET. SEAL ALL ACCESSIBLE OPENINGS
Mar 21, 2012 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jan 13, 2011 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Aug 21, 2009 V-DOB VIOLATION - ACTIVE A-SEU NONE A-SEU NONE
May 26, 2009 VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WORK W/OUT PERMIT
Apr 17, 2009 VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WORK W/OUT PERMIT
Mar 29, 2001 VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE P-PLUMBING NONE PLUMBING WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED SPRINKLER WORK IN HALLWAY ON 3RD & 4TH FLRS. PIPING NOT AS PER CODE AND NO PERMIT REMEDY: OBTAIN A PERMIT IF FEASIBLE OR RESTORE TO PRIOR LEGAL CONDITION
Mar 22, 2001 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL HAZARDOUS
Mar 22, 2001 VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WORK WITHOUT A PERMIT. NOTED: PARTITIONS INSTALLED THRU-OUT BLDGS 2ND 3RD & 4TH FLOORS CREATING 13 CLASS "A" & CLASS "B" UNITS, SEPARATIONS BETWEEN UNITS & PUBLIC HALLS ARE NOT RATED AS PER CODE. ENTRY DOORS & FRAMES NOT RATED, 9 UNITS ARE BLOCKED FROM ACCESS TO REAR FIRE ESCAPE WITH NO 2ND MEANS OF EGRESS. WORK 100% COMPLETED. REMEDY: OBTAIN PERMI
Aug 23, 2000 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL HAZARDOUS