NYC Building Report

Brooklyn Bushwick (East)

21 Eldert Street, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

11 records

Date Status Type Summary
Jul 31, 2020 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL 1) INSTALL 20' OF TEMPORARY SHORING FROM CELLAR TO ROOF ALONG EXP 4 AT CORNER WITH EXP 3. 2) INSTALL EXTERIOR TEMPORARY BRACING AT THE EXP#3 WALL. 3) REMOVE ALL LOSE STUCCO FROM EXPOSURE 3 AND 4
Jul 30, 2020 V-DOB VIOLATION - ACTIVE UB-UNSAFE BUILDINGS NONE UB-UNSAFE BUILDINGS NONE
Jul 20, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERG WORK-BLDG STATE DISREPAIR.SPALLING BRICK&STUCCO AT REAR WALL AND BULGING WALL AT 2FLR.AT SIDEWLK A SECTION 7'X8'HAS DETACHED AND FALLEN ON ADJ LOT.THE REMAINDER OF STUCCO IS AT RISK FALLING AND WALL AT RISK OF COLLAPSE.IMMED BRACE REAR WALL AND REMOVE LOOSE STUCCO UNDER DIRECT CONTINUOUS SUPERVISION PE.FILE FOR PRMT NO LATER THA 48 HOURS WRK STRT
Jul 16, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:DETACH BLDG IN STATE OF DISREPAIR.ON EAST WALL SECTION APROX 8'X7' OF STUCCO@THE 3RD FLR HAD DETACHD&FALLEN ON THE ADJ LOT.CRNR OF NORTH &EAST WALL IS BOWING OUTWRD FROM 2FLR-GRADE.REAR WALL IS STRUCTURALLY IN DANGER OF COLLAPSE RENDERING BLDG UNSAFE TO OCCUPY.FULL VACATE OF ENTIRE BLDG UNTIL THE CONDITIONS ABOVE ARE REPAIRED UNDER PERMIT
Feb 7, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #322228 TO IMMEDIATELY BRACE REAR WALL AND REMOVE LOSE STUCO AND FILE FOR PERMIT BY 01/16/20 AS OF 2/7/20 THERE ARE NO JOBS FILED AND NO WORK DONE.IMMEDIATLEY FILE FOR PERMITS TO COMPLY WITH COMMISSIONER'S ORDER # 322228
Feb 7, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #315867 ISSUED ON 12/20/19 TO OBTAIN PERMIT AND START REPAIR WORK BY 1/20/20.AS OF 2/7/20 THERE ARE NO PRMTS OBTAIN OR JOB FILED.IMMEDITELY COMPLY WITH COMMISSIONER'S ORDER # 315867
Jan 3, 2020 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER:3ST+B+C BLDG STATE OF DISREPAIR.SPALLED BRICK AND STUCCO NOTED AT REAR WALL.BOWING OF REAR WALL NOTED AT 1ST&2ND FLOORS CRACKED STUCCO IN DANGER OF FALLING NOTED @ SIDE WALL.IMMED BRACE REAR WALL AND REMOVE ALL LOSE STUCCO&BRICK.WRK TO BE PERFORMED UNDER DIRECT AND CONTINUOUS SUPERVISION OF PE.FILE NO LATER THAN 1/16/20
Dec 20, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM:3STY+B+CELLAR.BLDG IN STATE OF DISREP SPALLED AND CRACK BRICKS AND STUCCO NOTED AT REAR WALL AT 1ST,2ND & 3RD FL.CRACK NOTED AT SIDE WALL FROM 1ST TO ROOF.WATER DAMAGE NOTED@INTERIOR@REAR WITH ROTTED JOIST AT 1ST,2ND,&3RD FLRS.OWNR ENGAGE NYS LICENSED PE AND CONTRACTOR TO REPAIR BUILDING UNDER PERMIT.FILE FOR PERMIT BY 1/6/20.START WORK BY 1/20/20
Dec 19, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DUE TO VERTICAL 1 1/2 CRACKS AT EXP.#4, BUILDING FACADE EXP.#3 AND DIAGONAL CRACKING AROUND REAR WINDOWS FROM CONSTRUCTION OF A NEW 4 STORY BUILDING AT 25 ELDERT STREETAND ALSO FROM WATER DAMAGE DUE TO R EAR IN WALL AND ROOF
Dec 19, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DUE TO VERTICAL 1 1/2 CRACKS AT EXP. 4, BUILDI NG FACADE AT EXP. 3
Jul 9, 2019 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL OBSERVED HORIZONTAL / VERTICAL CRACKS, DISLODGED AND BULGING STUCCO IN EXTERIOR FACADE ALL OVER EXPO # 04. UNABLE TO DETERMINE THE CAUSE OF FACADE DETERIORATION.