Brooklyn East Flatbush-Farragut
2093 Nostrand Avenue, Brooklyn
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-05005-0012), so they can include other buildings on the same lot.
66 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jul 22, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE SPRING AT UPPER AND LOWER SASH. IN THE KITCHEN LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | A | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: REFIT UPPER AND LOWER SASH AT WINDOW. IN THE KITCHEN LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE FAUCET AT SINK. IN THE BATHROOM LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING AND EAST WALL. IN THE BATHROOM LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT NORTH WINDOW. IN THE 4th ROOM FROM EAST LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE SPRING AT LOWER SASH AT WINDOW. IN THE 5th ROOM FROM EAST LOCATED AT APT 1, 2nd STORY |
| Jul 22, 2002 | A | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: REFIT LOWER SASH AT WINDOW IN THE 5th ROOM FROM EAST LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STEAM RADIATOR SHUT-OFF VALVE KNOB IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR AT RADIATOR IN THE 1st ROOM FROM EAST LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOOR MOLDING IN THE FOYER LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | A | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ESCUTCHEON RING AT SHOWER HEAD IN THE BATHROOM LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | A | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUTING CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES IN THE BATHROOM LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASEBOARD AT SINK IN THE KITCHEN LOCATED AT APT 1, 2nd STORY |
| Feb 5, 2002 | B | NOV SENT OUT | 1 | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH WINDOW IN THE KITCHEN LOCATED AT APT 1, 2nd STORY |