| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Oct 13, 2026 | B | NOV SENT OUT | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Oct 13, 2026 | B | NOV SENT OUT | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Oct 13, 2026 | B | NOV SENT OUT | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Oct 13, 2026 | A | NOTICE OF ISSUANCE SENT TO TENANT | 1A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT OBSERVED AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Oct 13, 2026 | B | NOV SENT OUT | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Oct 8, 2026 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DOOR PULL AT BUILDING ENTRANCE DOOR |
| Oct 8, 2026 | C | NOV SENT OUT | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT COMPACTOR CLOSET, 2nd STORY |
| Aug 4, 2026 | C | CIV14 MAILED | 3B | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY |
| Aug 4, 2026 | B | CIV14 MAILED | 3B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE WINDOW STOOL IN THE 1st ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY |
| Aug 4, 2026 | C | CIV14 MAILED | 2B | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Aug 4, 2026 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 2B | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Aug 4, 2026 | A | NOTICE OF ISSUANCE SENT TO TENANT | 1H | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Aug 4, 2026 | B | CIV14 MAILED | 1D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD GREATER THAN 10SQ FEET AT CEILING,WEST AND NORTH WALL IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Aug 4, 2026 | B | CIV14 MAILED | 1D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 1D, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 21, 2026 | C | VIOLATION DISMISSED | 6D | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SLIDE BOLT WITH EYE CAPABLE OF BEING PADLOCK IN THE ENTRANCE LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 21, 2026 | B | CIV14 MAILED | 6D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 21, 2026 | A | NOTICE OF ISSUANCE SENT TO TENANT | 6D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 21, 2026 | B | CIV14 MAILED | 6D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | B | CIV14 MAILED | 6D | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | B | CIV14 MAILED | 6D | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | B | VIOLATION CLOSED | 6D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND CEILING IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | A | VIOLATION CLOSED | 6D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | B | VIOLATION CLOSED | 6D | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jul 15, 2026 | B | VIOLATION CLOSED | 6D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| Jun 27, 2026 | A | VIOLATION CLOSED | 2B | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH AT WEST, THE PRIVATE HALLWAY , THE 1st ROOM FROM NORTH AT EAST, THE 2nd ROOM FROM NORTH AT EAST, THE KITCHEN , THE 2nd ROOM FROM NORTH AT WEST, THE FOYER , THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jun 27, 2026 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM |
| Jun 27, 2026 | C | NOT COMPLIED WITH | 2B | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jun 27, 2026 | A | VIOLATION CLOSED | 2B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL GFI OUTLET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jun 27, 2026 | A | NOT COMPLIED WITH | 2B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 3 SQ OF MOLD AT SOUTHB WALL SOUTH WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jun 9, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR ROOM DOOR AT BASEMENT |
| Jun 9, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT LAUNDRY ROOM DOOR AT BASEMENT |
| May 1, 2026 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Apr 22, 2026 | B | VIOLATION CLOSED | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT 1ST WINDOW FROM WEST AT NORTH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 13, 2026 | C | VIOLATION CLOSED | Not available | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT LIVE RATS AT BASEMENT |
| Apr 13, 2026 | B | VIOLATION CLOSED | Not available | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT BASEMENT |
| Apr 13, 2026 | B | VIOLATION CLOSED | 1A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Apr 13, 2026 | B | VIOLATION CLOSED | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Apr 4, 2026 | B | VIOLATION CLOSED | Not available | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES AT BASEMENT AT PUBLIC HALL |
| Apr 4, 2026 | C | VIOLATION DISMISSED | 1A | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Apr 4, 2026 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM |
| Apr 4, 2026 | A | VIOLATION CLOSED | 1A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Apr 4, 2026 | B | VIOLATION CLOSED | 1A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Apr 4, 2026 | B | VIOLATION CLOSED | 1A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' |
| Mar 29, 2026 | A | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVERS FOR ELECTRICAL OUTLETS AT EAST, SOUTH AND WEST WALLS AT PUBLIC HALL, 1st STORY |
| Mar 29, 2026 | A | VIOLATION CLOSED | Not available | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE |
| Mar 29, 2026 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CARPET, FLOWER POT AND HOUSEHOLD ITEMS AT 1ST FROM EAST AT BUILDING FRONT AT FIRE ESCAPE, 5th STORY |
| Mar 1, 2026 | A | VIOLATION CLOSED | Not available | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE |
| Mar 1, 2026 | C | VIOLATION DISMISSED | 1K | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1K, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT WEST |
| Jan 15, 2026 | C | VIOLATION DISMISSED | 5A | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH |
| Jan 15, 2026 | B | VIOLATION DISMISSED | 5A | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH |