Brooklyn Gravesend (East)-Homecrest
1880 Coney Island Avenue, Brooklyn
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
7 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Feb 21, 2018 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | EMERG WRK.SINGLE STORY COMM BLDG.PORT OF ROOF SUPPORTED BY TIMBER BOWSTRING TRUSSES.EASTMOST BOWSTRING TRUSS DETERIORATED @SOUTH BEARING TENSION TIE HAS MULT LONG CRACKS EMINATING FROM BEAR AREA&DEFORMED DOWNWARD.REMEDY:RET NYS LIC PE TO PREP PLANS TO SHORE DEFECT TRUSSES SHORING BE IMPLEMENTED BY 2/22/18.PLANS BE FILED W/DEPT W/48HRS |
| Feb 21, 2018 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | 1ST BOW STRING TRUSS AT THE EAST END OF PREMISES W/ CRACKS AND DEFECTS RENDERING SITE/LOCATION TO BE UNSAFE AND IN DANGER OF COLLAPSE |
| Sep 28, 2015 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | 1 STORY COMMERCIAL STRUCTURE W/A WOOD BOWSTRING TRUSS ROOF. REMEDY: W/IN 60 DAYS OF DATE OF VIO OWNER TO ENGAGE A NYS LIC PE EXP'D W/WOOD TRUSSES TO PROBE & EVAL STRUCTUAL SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS CALCULATIONS ETC & SUBMIT A REPORT ACCEPTABLE T/THE DEPT DRWGS T/BE FILED W/THE DOB W/IN 45 DAYS AFTER THE INSPECTION |
| Sep 17, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WITH A COMMISSIONER'S ORDER. THE BUILDING IS A WARE- HOUSE-TYPE STRUCTURE WITH A WOOD BOWSTRING TRUSS/ROOF. THE DEPARTMENT SERVED YOU WITH A CURABLE COMMISSIONER'S ORDER (NOTICE OF VIOLATION) TO PRODUCE AN ENGINEER'S REPORT ON YOUR BUILDING. NO ENGINEER'S REPORT HAS BEEN RECEIVED |
| Jun 13, 2014 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | THIS BUILDING HAS A WOOD BOWSTRING TRUSS ROOF BY 60 DAYS FROM VIOLATION, HAVE NYS LICENSED PE EVAL. EACH BOWSTRING TRUSS AND BEARINGS VIA FIELD VERIFICATION, CALCULATIONS, PROBES, ETC ANY STRUCTURAL DEFICIENCIES TO BE IMMEDIATELY SHORED. REPAIR DRAWINGS TO BE FILED WITH THE DOB WITHIN 45 DAYS AFTER INSPECTION |
| Jan 26, 2001 | VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | WORK WITHOUT PERMIT. WORK NOTED: FENCE APPROX 60'X 8' INSTALLED AROUND BLDG WITH A 32' HIGH SCAFFOLD INSTALLED FOR OUTSIDE EXTERIOR WORK REMEDY: OBTAIN PERMIT |
| Jan 25, 2001 | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | WORK WITHOUT A PERMIT. EXPIRED PERMIT. PERMIT #30108570-01 OBTAINED FOR CONSTRUCTION EQUIPMENT FENCE EXPIRED 12/31/2000 REMEDY: RENEW PERMIT |