Brooklyn Bensonhurst
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
2 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Aug 20, 2009 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO PROVIDE ANCHORAGE OF FLOOR JOIST TO MASONRY WALLS NOTED: NE W 3X10 WOOD JOISTS INSTALLED @ 16" O.C APPROX 14 EACH AT EACH FLOOR ME TAL ANCHORS AT 72" O.C. MAXIMUM NOT OBSERVED AT CELLAR (FLOOR 1 &2 ARE CVERTED) ALSO NO BLOCKING INSTALLED AT CELLAR REMEDY: PROVIDE PROPER ANCHORAGE AT ALL FLOORS CALL FOR VISUAL INSPECTION OR PROVIDE VERFICAT |
| Aug 20, 2009 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | INADEQUATE DETAILS/SPEC ON APPROVED PLANS FOR CONNECTION OF STRUCTURAL STEEL GIRDER APPROX W8X22 I BEAMS AT CELLAR SUPPORTING FLOOR JOISTS A T FLOOR1 TWO BEAMS ARE CONNECTED IN PLACE WITH SPOT WELD 1 OR 2 SPOTS ON EACH OF 3 SIDES ALSO NO REQUIRMENTS ON APPROVED PLANS FOR JOIST ANC HORAGE REMEDY: PROVIDE PE SHOP DRAWING WITH CONNECTION AND ANCHORAGE D |