| Jun 26, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR AT CHIMNEY AT EAST AT ROOF |
| Jun 26, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT VESTIBULE AT BUILDING ENTRANCE |
| Jun 26, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT SCUTTLE LADDER AT PUBLIC HALL, 3rd STORY |
| Apr 29, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 29, 2019 | B | VIOLATION CLOSED | 6 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 23, 2019 | C | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION FROM WATER SUPPLY PIPE TO THE SPRINKLER HEAD LOCATED AT THE EAST WALL AT CELLAR |
| Apr 23, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE CEILING AT CELLAR |
| Apr 23, 2019 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE VESTIBULE , 1st STORY |
| Apr 23, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL IN VESTIBULE , 1st STORY |
| Apr 23, 2019 | B | VIOLATION CLOSED | Not available | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN VESTIBULE , 1st STORY |
| Apr 23, 2019 | B | VIOLATION CLOSED | 6 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 23, 2019 | C | VIOLATION CLOSED | 6 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE TEMPERATURE OF 130 DEGREES FAHRENHEIT AT THE HOT WATER FIXTURE IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Apr 8, 2019 | A | NOT COMPLIED WITH | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .. AT PUBLIC HALL, 1st STORY |
| Apr 8, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOUSHOLD ITEMS OBSTRUCTING SCUTTLE LADDER AT PUBLIC HALL, 3rd STORY |
| Mar 22, 2019 | B | VIOLATION CLOSED | 4 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 22, 2019 | B | VIOLATION CLOSED | 4 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 22, 2019 | C | VIOLATION CLOSED | 4 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER AT ALL FIXTURES EXCEEDING THE MAXIMUM ALLOWABLE TEMPERATURE OF 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 22, 2019 | C | VIOLATION CLOSED | 4 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 18, 2019 | C | VIOLATION CLOSED | 4 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 12, 2019 | B | VIOLATION CLOSED | 6 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 12, 2019 | C | VIOLATION CLOSED | 6 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 26, 2019 | B | VIOLATION CLOSED | Not available | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING DEBRIS (APPROX 3 CUBIC YARDS) AT NORTH YARD |
| Feb 19, 2019 | C | VIOLATION CLOSED | 5 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | C | VIOLATION CLOSED | 5 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 5, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | VIOLATION CLOSED | 6 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | VIOLATION CLOSED | 6 | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES WALL OUTLET AT WEST IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | C | VIOLATION CLOSED | 6 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | C | VIOLATION CLOSED | 6 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | VIOLATION CLOSED | 6 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | VIOLATION DISMISSED | 6 | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Feb 19, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORY |
| Feb 19, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD TREADS # 11 THRU 14 FROM INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 2nd STORY |
| Feb 19, 2019 | C | VIOLATION CLOSED | Not available | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT PUBLIC HALL, 2nd STORY |
| Feb 19, 2019 | C | VIOLATION CLOSED | Not available | § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE RAW SEWAGE AT CELLAR AT WEST |
| Feb 19, 2019 | B | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE PROVIDE SUITABLE TIGHT COVER FOR THE HANDHOLE OPENING OF TRAP AT CELLAR AT SOUTH |
| Feb 19, 2019 | C | VIOLATION CLOSED | Not available | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN IN WASTELINE AT CELLAR AT SOUTH |
| Feb 19, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD TREAD # 6 FROM BOTTOM UP AT PUBLIC HALL STAIRS, 1st STORY |
| Feb 5, 2019 | B | VIOLATION CLOSED | Not available | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT PUBLIC HALL, 2nd STORY |
| Feb 5, 2019 | A | VIOLATION CLOSED | Not available | §27-2153 ADM CODE POST AND MAINTAIN A NOTICE, WRITTEN IN ENGLISH AND IN SPANISH, ON THE BUILDING ENTRANCE DOOR OR OTHER CONSPICUOUS LOCATION IN THE BUILDING COMMON AREA, STATING THAT: (1) THE BUILDING IS IN THE ALTERNATIVE ENFORCEMENT PROGRAM, (2) THAT OCCUPANTS MAY CALL 311 OR THE AEP AT 212-863-8262 TO REPORT HOUSING MAINTENANCE COMPLAINTS, (3) THE NAME, TELEPHONE, AND ADDRESS OF THE OWNER, AND, (4) THE IDENTITY OF ANY FINANCIAL INSTITUTION THAT HOLDS A MORTGAGE ON THE PROPERTY. POST |
| Jan 31, 2019 | I | INFO NOV SENT OUT | Not available | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WILL BECOME LIENS ON THE PROPERTY |
| Dec 12, 2018 | B | VIOLATION CLOSED | 4 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 12, 2018 | B | VIOLATION CLOSED | 4 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 12, 2018 | C | VIOLATION CLOSED | 4 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXCCEDS THE MAXIMUM ALLOWABLE OPERATING TEMPERATURE OF 130F(142 FOUND) THERMOMETR #92156 IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 12, 2018 | C | VIOLATION CLOSED | 4 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Nov 26, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 6TH TREAD UP FROM 1ST STORY PUBLIC HALL AT PUBLIC HALL STAIRS |
| Nov 14, 2018 | B | VIOLATION CLOSED | Not available | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUBLIC HALL, 2nd STORY |
| Nov 14, 2018 | B | NOT COMPLIED WITH | Not available | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE AT PUBLIC HALL, 1st STORY |
| Nov 14, 2018 | A | VIOLATION DISMISSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| Nov 14, 2018 | B | VIOLATION CLOSED | 6 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |