Brooklyn East Williamsburg
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
24 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jul 29, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING WALLS, VERTICAL AND HORIZONTAL CRACKS OBSERVED AT EXPOSURE 3 WALL. CONCREATE FLOOR AT EXPOSURE 3 EXTERIOR HAS SEVERE DAMAGE DUE TO EROSION. |
| Feb 5, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #350482(012126FEU30102BP) DATED 1/22/26 REQUIRING OWNER TO IMMED ERECT TGHTBRD FNCE TO SECURE THE CLLPSE ZONE TO THE 2ND COL BAY&PREVNT UNAUTHORIZD ACCESS TO THE REAR 50FT OF THE BLDG&REAR YRD AS REQ'D,&FILE FOR PRMT W/IN 2DAYS FROM STRT OF WRK.AS OF 2/5/26,DOB HAS NOT RECEIVD ANY SUPPORTNG EVIDENCE |
| Feb 3, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY W/COMMISSIONER'S ORDER #350483(012126FEU30103BP) DATED 11/22/26 REQUIRING OWNER TO IMMEDIATELY SUBMIT MEANS&METHODS FOR REVIEWING/APPROVAL&PRTLLY DEMO&TEMP BRACE/SHORE STBLIZE THE BLDG UNDER FULLTIME PE SPRVSN.AS OF 2/5/26,FEU HAS NOT RECEIVD PROPOSD MEANS& METHDS FOR OUR REVIEW&APPRVL.IMMED COMPLY W/COMMISSIONER'S ORDER350483 |
| Jan 21, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER.EXP2/3 CORNER COLUMN UNSUPPORTD DUE TO PRTLLY CLLPSD/COMPROMISD TIMBER PILES&CONCRETE GRADE BEAM/PILE CAP FOUNDATN REAR 25FT DEEP BAY STRUC COMPROMISD&AT RISK OF COLLAPSE.OWNR TO IMMED RTAIN NYSPE&DEMO ENDRSD GC TO 1.SUBMT MEANS & METHDS TO FEU,2.PRTLLY DEMO THE REAR BLDG.TEMP BRACE/SHORE |
| Jan 21, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER.EXP2/3 CORNER COLUMN UNSUPPORTD DUE TO PRTLLY CLLPSE/COMPROMSD&AT RISK OF CLLPSE.EXTERIOR EXP2&EXP3 CMU WALLS CRCKD SETTNG&AT RISK OF COLLAPSE.IMMED ERECT TGHTBRD FENCE TO SECURE THE CLPSE ZONE TO THE 2ND COLUMN BAY&PREVENT UNAUTHORIZD ACCES TO THE CLLPSE ZONE |
| Nov 17, 2025 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED SECTION OF CONCRETE AT REAR YARD OF A ONE STORY COMMERCIAL BUILDING WHICH IS APPROX 10X20. PARTIALLY COLLAPSED AND IS IN A STATE OF DISREPAIR. ALSO OBSERVED AT EXPOSURE 3 EXTERIOR WALL CRACKS IN VARIOUS LOCATIONS |
| Sep 23, 2024 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION |
| Apr 25, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION |
| Apr 29, 2021 | V-DOB VIOLATION - ACTIVE | EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE | FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 |
| Nov 8, 2019 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT |
| Apr 6, 2018 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT |
| Feb 24, 2017 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT |
| Oct 1, 2015 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT |
| Mar 3, 2015 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT |
| May 15, 2014 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT |
| Jan 1, 2009 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 19, 2007 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 13, 2004 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 16, 1999 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jul 25, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |