NYC Building Report

Brooklyn Williamsburg

147 Roebling Street, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

148 records

Date Status Type Summary
Nov 14, 2025 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Nov 3, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE AT THE TIME OF INSPECTION,I OBSERVED ON EXP1,CRACK SILL ON 3RD FL,BROKEN WINDOW PA NES ON 4TH AND 5TH FL,STEP CRACK IN 3RD FL SPANDRELS AT MULTIPLE LOCAT IONS.EXP2 NORTH ELEV,BROKEN AND MISSING WINDOW PANE,MISSING MORTAR JOI NT AT PARAPET AND SEVERAL OTHER LOCATIONS.REMEDY:REPAIR OR REPLACE
Nov 3, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EWO DUE TO IMMINENT HAZARDOUS CONDITION ON BULK HEAD @ SOUTH-EAST CORNER OF EAST ELEV.LOOSE BULGING BRICKS, STEP CRACKS, LOOSE OPEN MORTAR JOINT, CORRODED SAGGING METAL LINTELS,BROKEN WINDOW PANES REMEDY: IMMEDIATELY PROVIDE SAFE MEAS TO PROTECT PUBLIC U/SUPV OF NYC LIC PROF.SIDEWALK SHED ON EXP3 MUST BE EXTENDED PASS BULK HEAD OF BLDG
Aug 7, 2024 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
May 21, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.BLDG SUFFERED A FAILURE TO MAINTAIN CONDITION@ALL EXPOSURES&INT THE EXT WALLS ONE EXP1&4 HAD SEVERE CONCRETE CRCKS&SPALLD EXPOSD REBAR TO BEAM&LANDING.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DTRMINE THE STRCTRL STBILITY,& PREPARE//FILE RPAIR DWGS.BLDG TO BE RPAIRDED
May 21, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.BLDG SUFFERED FROM A FAILURE TO MAINTAIN CONDITIONS@ALL EXPOSURES&ROOF.THE ROOF JOISTS, GIRDR&POSTS HAD VARIOUS CRCKS&WERE STRCTRLLY COMPROMISED.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DETERMINE THE STRCTRL STBILITY& PREPARE/FILE RPAIR DWGS.BLDG TO BE RPAIRD
May 21, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.THE BLDG SUFFRD FRM FAILURE TO MAINTAIN CONDITIONS@ALL EXPOSURES&THE ROOF.FLR JOSTS, GIRDER,POST HAD VARIOUS CRCKS&WERE STRCTRLLY COMPROMISED.OWNR TO IMMED RTAIN NYSPE TO EVAL ENT BLDG,DTRMINE STRCTRL STBILITY,&PREPARE/FILE RPAIR DWGS.BLDG TO BE RPAIRD UNDR PRMT
May 21, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.THE BLDG SUFFRD FRM FAILURE TO MAINTAIN CONDITIONS@ALL EXPOSURES&ROOF.VARIOUS CRCKS OBSRVD PN EXT&INT OF ALL EXP FLR JOISTS,GIRDERS,POSTS HAD VARIOUS CRCKS&WERE STRCTRLLY COMPROMISED.OWNR TO IMMED RTAIN NYSPE TO EVAL ENT BLDG, DETERMNE STRCTRL STBILITY,&PREPARE/FILE RPAIR DWGS.BLDG TO BE RPAIRD
May 20, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAITAIN BUILDING IN CODE COMPLIAANT MANNER . EXTERIOR, INTE RIOR CRACKS THROUGHOUT BUILDING ALLOWING WATER TO SEEP IN CAUSING WAT ER DAMAGE . DUE TO FAILURE TO MAINTAIN THIS 5 STORY BUILDIGN , THE PA RAPET HAS PARTIALLY COLLAPSED COMPROMISING STRUCTURAL STABILITY + SEC ONDARY MEANS OF EGRESS
May 20, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FILURE TO MAITAIN BUILDING IN CODE COMPLIANT MANNER . EXTERIOR AND INT ERIOR CRACKS THROUGHOUT THE BUILDING ALLOWIING WATER TO SEEP IN AND CA USE WATERR DAMAGE. THIS 6 STORY BUILDING HAS BECOME STRUCTURALLY COMP ROMISED DUE TO FAILURE TO MAINTAIN STRUCTURAL DEFECTS THROUGHTOUT
May 20, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER EXTERIOR & INTERIORCRACK S THROUGHTOUT THE BUILDING ALLOWING WATER TO SEEP INADEQUATE WATER DAM AGE. THIS 6 STORY BUILDING HAS BECOME STRUCTURALLY COMPROMISED DUE TO FAILURE TO MAITAIN STRUCTURAL DEFECTS THROGHOUT
May 20, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER.ON 5/19/24,THE PARAPET ALONG EXP4 HAD PARTIALLY CLLPSD DMGNG DELAMINGLE LEANING OUTWRD.LOOSE BRCKS MISSNG MOTOR JOINTS BRCKS THE SDWALK SHED&ADJCNT VEHICLES ON THE STREET.OWNR TO IMMED RTAIN NYSPE&DOB REG HC TO 1.IMMED PRVDE TEMP SHORNG&BRACNG INSIDE THE BLDG TO STABILIZE EXP4 WALL
May 19, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL STRCUTURE RENDERED NON COMPLIANT -SIDEWALK SHED COLLAPSE DUE TO FALLI NG DEBRIS COLLAPSED OF THE PARAPET WALL ON HOPE STREET
May 19, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMLIANT MANNER. APROXIMATELY 75 LINEAR FEET SECTION COLLAPSED ONTO THE SIDEWALK SHED & STREET OWNER TO HIRE A NYSPE TO SUBMIT REPORT TO ERTINSPCTIONS@BUILDING.NYC GOV WIHTIN 14 DAYS ADDRESSING THE CONDITION WITH PLANS, PHOTOS, TIME F RAME TO BE COMPLETED
Oct 4, 2023 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Jun 30, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Jun 20, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Apr 25, 2023 V-DOB VIOLATION - ACTIVE LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
Mar 14, 2022 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL TO ERECT ATOTAL OF APPROXIMATELY 455 LINEAR FEET OF SIDEWALK SHED.WITH APPROXIMATELY 160 LINEAR FEET ALONG ROEBLING STREET, APPROXIMATELY 190 LINEAR FEET ALONG HOPE STREET AND APPROXIMATELY 105 LINEAR FEET ALONG METROPOLITAN AVENUE TO SAFEGUARD THE PUBLIC AND PROPERTY
Mar 14, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION, OBSERVED PARAPET WALL IN STATE OF DISREPAIR WITH SECTION DISLODGE AND FALLEN ONTO SIDEWALK, WITH MISSING MORTAR THROUGHOUT. OBSERVED ALSO SOME INTERIOR CRACK
Dec 17, 2021 V-DOB VIOLATION - ACTIVE EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
Dec 17, 2021 V-DOB VIOLATION - ACTIVE EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
Dec 17, 2021 V-DOB VIOLATION - ACTIVE EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
Dec 17, 2021 V-DOB VIOLATION - ACTIVE EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED FAILURE TO PERFORM CATEGORY 5 INSPECTION
Sep 6, 2019 V-DOB VIOLATION - ACTIVE ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
Sep 6, 2019 V-DOB VIOLATION - ACTIVE ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
Sep 6, 2019 V-DOB VIOLATION - ACTIVE ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST