Brooklyn Bushwick (East)
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 3-03306-0054), so they can include other buildings on the same lot.
157 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Mar 1, 2022 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| May 20, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF HASP WITH LOCKABLE EYE ON GATE AT BUILDING FRONT |
| Mar 27, 2019 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRONIC BELL SYSTEM AT ENTRANCE TO BUILDING |
| Jan 2, 2019 | C | SECOND NO ACCESS TO RE-INSPECT VIOLATION | 1R | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER AT HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 29, 2018 | A | VIOLATION CLOSED | Not available | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT WEST DROP LADDER , REAR STACK |
| Oct 29, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING BRACE AT 2ND STORY BALCONY REAR STACK |
| Oct 29, 2018 | B | VIOLATION CLOSED | 1R | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 29, 2018 | A | VIOLATION CLOSED | 1R | § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO MISSING CHAIN GUARD IN THE ENTRANCE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 29, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 29, 2018 | B | VIOLATION CLOSED | 1R | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE OF SINK IN THE KITCHEN LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 29, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 ADM CODE REMOVE THE TORN AND/OR LOOSE FLOOR COVERING ''VINYL COVERING'' IN THE KITCHEN LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 29, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 5 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 13, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSTRUCTION DEBRIS AT REAR WEST YARD |
| Oct 13, 2018 | B | VIOLATION CLOSED | Not available | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING ONE OR MORE LIGHTS WITH AN AGGREGATE OF NOT LESS THAN 200 WATTS INCANDESCENT OR EQUIVALENT. |
| Oct 13, 2018 | C | VIOLATION DISMISSED | Not available | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSTRUCTION DEBRIS APPROX. 20 CU. YDS. AT BUILDING FRONT YARD |
| Oct 13, 2018 | C | VIOLATION DISMISSED | 1R | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOTWATER EXCEEDING THE MAXIMUM TEMPERATURE AT OF 130 DEGREES AT ALL HOTWATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 13, 2018 | C | VIOLATION CLOSED | 1R | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 10, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING STAIRS WITH ALL TRADS AND RISERS AT CELLAR |
| Oct 10, 2018 | C | VIOLATION CLOSED | 3R | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE STOPPING MATERIALS AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | C | VIOLATION CLOSED | 3L | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE STOPPING MATERIALS AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2018 | C | VIOLATION CLOSED | 2L | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE STOPPING MATERIALS AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE STOPPING MATERIALS AT CEILING AND ALL WALLS AT CELLAR |
| Oct 10, 2018 | C | VIOLATION DISMISSED | 1L | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE STOPPING MATERIALS AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 10, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF ... AT PUBLIC HALL, 3rd STORY |
| Oct 10, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT EXTRIOR WALL FRONT OF THE BUILDING |
| Oct 10, 2018 | C | VIOLATION DISMISSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSTRUCTION MATERIALS AT FRONT YARD |
| Oct 10, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSTRUCTION MATERIALS AT REAR YARD |
| Oct 10, 2018 | C | VIOLATION DISMISSED | 1R | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES STOVE IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION DISMISSED | 1R | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL COVERING OT FLOOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL COVERING AT FLOOR IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION CLOSED | 1R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | C | VIOLATION DISMISSED | 1R | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ELECTRICAL EXTENTION CORDS IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | C | VIOLATION DISMISSED | 1R | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION DISMISSED | 1R | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 10, 2018 | B | VIOLATION DISMISSED | 1R | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 5, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOCED ELEXTIRC WIRES AT CEILING 2ND STORY PUBLIC HALL |
| Oct 5, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT VESTIBULE 1ST STORY PUBLIC HALL |
| Oct 5, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING ONE OR MORE LIGHTS WITH AN AGGREGATE OF NOT LESS THAN 100 WATTS INCANDESCENT OR EQUIVALENT |
| Oct 4, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING METAL TREADS, SLATS AND BATTEN AT REAR FIRE ESCAPE AT FIRE ESCAPE |
| Oct 4, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROVIDE FIRE WATCH TO ENTIRE BUILDING |
| Sep 25, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF BX CABLE EXPOSED ALL STYS. AT PUBLIC HALL |
| Sep 25, 2018 | A | VIOLATION CLOSED | Not available | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS ALL STYS AT PUBLIC HALL |
| Sep 25, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AND WALLS ALL STYS. AT PUBLIC HALL |
| Sep 25, 2018 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING AT BULKHEAD ROOF |
| Sep 25, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF AT BULKHEAD |
| Sep 25, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BOILER ROOM AT CELLAR |
| Sep 25, 2018 | B | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT WINDOW FRONT OF CELLAR AT CELLAR |
| Sep 25, 2018 | B | VIOLATION DISMISSED | Not available | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF BX CABLE EXPOSED THROUGHOUT CELLAR AT CELLAR |