| Jun 1, 2022 | C | NOT COMPLIED WITH | 2R | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT EAST WALL CIRCUIT BREAKER BOX IN THE PRIVATE HALLWAY LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | NOTICE OF ISSUANCE SENT TO TENANT | 4R | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT THE APARTMENTS SOUTH DOOR IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER GLASS PANE AT 1ST WINDOW ON SOUTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING LIGHT FIXTURE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | A | VIOLATION CLOSED | 4R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WSAH BASIN WASTE PIPE IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SECURITY GATE AT FIRE ESCAPE WINDOW IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL AT FOYER, 4th STORY, APARTMENT |
| Jun 1, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND WEST WALL AT FOYER, 4th STORY, APARTMENT |
| Jun 1, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT APPROXIMATELY 1SQFT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 15182252 ISSUED 25-MAY-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UNHINGED WOOD DOOR AT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ROTTEN BASE CABINET FLOOR, AT WEST WALL, IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | NOTICE OF ISSUANCE SENT TO TENANT | 4R | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | NOV SENT OUT | 4R | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR TO, ROOM WITH SECONDARY EXIT, NORTH WALL, IN THE 6th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT DOOR TO SECONDARY EXIT NORTH WALL, IN THE 6th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT LOWER SASH 1ST WINDOW FROM EAST AT SOUTH IN THE 6th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LOOSE CONNECTION AT RADIATOR EAST WALL IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | A | VIOLATION CLOSED | 4R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT APPROXIMATELY 1SQFT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | A | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER AT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AND NORTH , WEST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING AND EAST WALL IN THE FOYER LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | 4R | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE FOYER LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | B | NOV SENT OUT | 4R | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTICAL LIGHT SWITCH COVER AT SOUTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 25, 2022 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED AND SPLICED MASONRY WITH LOOSE PIECE( AT APPROXIMATELY 1'' -0'' BY 4 INCHES) , ADJACENT TO ENTRANCE AT FRONT AREAWAY, 3rd STORY |
| May 25, 2022 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LOSE IRON GUARDRAIL AND CRACKED MASONRY COPING STONE AT NGARDRAIL TO STAIR ENTRANCE TO BUILDING AT FRONT AREAWAY, 3rd STORY |
| May 25, 2022 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR WITH DISLOGED WOOD STOPPER , ENTRANCE TO BUILDING, AT FRONT AREAWAY, 3rd STORY |
| May 25, 2022 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY |
| May 25, 2022 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOSE PLASTER AT CEILING AT APPROXIMATELY 1SQFT ) AT PUBLIC HALL, 1st STORY |
| May 25, 2022 | B | NOV SENT OUT | Not available | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WOOD BALUSTERS ( 2) AT BALUSTRADE AT PUBLIC HALL STAIRS, 3rd STORY |
| May 11, 2022 | B | NOV SENT OUT | Not available | § 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUES. FAILURE TO PROVIDE DATA REQUESTED FOR OCTOBER 2021 TO DECEMBER 2021 |
| Apr 29, 2022 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 4R | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 15138710 ISSUED 29-APR-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Apr 29, 2022 | B | NOV SENT OUT | 2R | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT SWITCH COVER AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Apr 29, 2022 | C | NOT COMPLIED WITH | 2R | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF MISSING CIRCUIT BREAKER PANEL WITH EXPOSED WIRE AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Apr 29, 2022 | B | NOV SENT OUT | 2R | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD AT WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |