Date Class Status Apartment Summary
Mar 15, 2023 B VIOLATION WILL BE REINSPECTED 3J § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Mar 15, 2023 A VIOLATION CLOSED 3J § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Mar 15, 2023 A VIOLATION CLOSED 3J § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Mar 15, 2023 C VIOLATION CLOSED 3J § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Mar 15, 2023 A VIOLATION CLOSED 3J § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM NORTH AT EAST WALL, 1st RISER FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Mar 14, 2023 A VIOLATION CLOSED Not available § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Mar 14, 2023 C VIOLATION CLOSED Not available § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING [CARDBOARD JAMMED FIRE DOOR 1ST FROM NORTH AT WEST] AT PUBLIC HALL, 5th STORY
Mar 14, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE [FIRE DOOR 1ST FROM NORTH AT EAST] AT PUBLIC HALL, 5th STORY
Mar 5, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRE GLASS PANE AT WEST FIRE DOOR AT PUBLIC HALL, 6th STORY
Mar 5, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT WEST AT PUBLIC HALL, 6th STORY
Mar 5, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT EAST AT PUBLIC HALL, 6th STORY
Mar 5, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY
Mar 4, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY
Mar 1, 2023 B VIOLATION CLOSED 1B § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Mar 1, 2023 B VIOLATION CLOSED 1B § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE PIPE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Mar 1, 2023 B VIOLATION CLOSED 1B § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Feb 28, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT WEST AT PUBLIC HALL, 6th STORY
Feb 28, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT EAST AT PUBLIC HALL, 6th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT SECTION WEST AT PUBLIC HALL, 6th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT WEST SECTION AT PUBLIC HALL, 4th STORY
Feb 23, 2023 C VIOLATION CLOSED 6A § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED 6A § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED 6A § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED 6A § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR IN THE ENTRANCE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 C VIOLATION CLOSED 6A § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 A VIOLATION CLOSED 4B § 27-2005 ADM CODE REFIT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 C VIOLATION CLOSED 4B § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED 4B § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED 4B § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT EAST
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES THE SORAGE OF WINDOW GUARD AND HOUSEHOLD ITEMS AT, 4TH STORY BALCONY, SOUTHWEST SECTION , AT WEST YARD. AT FIRE ESCAPE
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIRCONDITIONER PROTRUSION AT WINDOW TO 4TH STORY BALCONY, SOUTHWEST SECTION , WEST YARD AT FIRE ESCAPE
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR , WEST SECTION, AT EAST WALL, AT PUBLIC HALL, 3rd STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR , EAST SECTION, WEST WALL, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 A VIOLATION CLOSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, NORTH AND EAST WALLS AT ROOF BULKHEAD , WEST SECTION, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS PLASTER AT CEILING, NORTH AND EAST WALLS, ROOF BULKHEAD , WEST SECTION, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR , WEST SECTION, EAST WALL, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WIRE GLASS AT FIRE DOOR , WEST SECTION, EAST WALL, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THR FIRE RETARDANT MATERIALS AT CEILING AND WEST WALL, WEST SECTION AT PUBLIC HALL, 6th STORY
Feb 23, 2023 A VIOLATION CLOSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WEST WALL , WEST SECTION, AT PUBLIC HALL, 6th STORY
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT WEST SECTION AT PUBLIC HALL, 6th STORY
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE CEILING AND NORTH WALL , WEST SECTION, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 A VIOLATION CLOSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AND CEILING AT PUBLIC HALL, 5th STORY
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE NORTH WALL AND CEILING , WEST SECTION, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 A VIOLATION CLOSED Not available § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL AROUND COMPACTOR CHUTE , WEST SECTION, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 B VIOLATION CLOSED Not available § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERILAS PLASTER AT SOUTH WALL TO COMPACTOR CHUTE , WEST SECTION, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PLEXI GLASS AT FIRE DOOR PANE , WEST SECTION, EAST WALL, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR WEST SECTION. EAST WALL, AT PUBLIC HALL, 5th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PLEXI GLASS AT FIRE DOOR PANE , EAST SECTION, WEST WALL AT PUBLIC HALL, 5th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR , EAST SECTION, WEST WALL , AT PUBLIC HALL, 5th STORY
Feb 23, 2023 C VIOLATION CLOSED Not available § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED WIRE GLASS AT FIRE DOOR WEST WALL AT PUBLIC HALL, 4th STORY