| Date | Status | Type | Summary |
|---|---|---|---|
| Jan 8, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | UNPERMITTED REAR UNDERPINNING & EXCAVATION STALLED >3 MOS, EXP#2 PARTY WALL CRACKED/SETTLED. PIERS UNDERMINED. NO REPAIR APPLICTN FILED. SITE NEEDS MONITORING. REMEDY: RETAIN NYS RDP. SUBMIT MONITORING PROTOCOL BY 1/16/26 FIRST REPORT BY 1/19/26. EMAIL ALL DOCS TO CSENGINEERING |
| Jun 25, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAIL2MAINTAIN, PERM REPAIRS REQ'D.ON 5/5/25 UNPERMITD UNDR-PINNING.AT EXP# 1,2,4 & >5' REAR EXCAVATION. PIERS UNDERMINED, CRACKS @ EXP# 2 PARTY WALL. REMEDY: FAILURE TO COMPLY W COMMISSIONER'S ORDR # 060225CE30201AD COMPLY W AFOREMENTIONED ORDER BY 7/3/25 |
| Jun 2, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAIL2MAINTAIN, PERM REPAIRS REQ'D.ON 5/5/25 UNPERMITD UNDRPINNING.AT EXP# 1,2,4 & >5' REAR EXCAVATION. PIERS UNDERMINED, CRACKS @ EXP#2 PARTY WALL. REMEDY: RETAIN NYS PE TO DESIGN PERM REPAIRS. SUBMIT TO CSENGINEERING BY 6/16. PERMIT/START BY 7/21, FINISH BY 10/21/25 |
| May 3, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURE RENDERED NON COMPLIANT. EXCAVATION AT THE LOCATION HAS UNDE RMINED THE RUBBLE STONE FOUNDATION WALL AT EXPOSURE # 4 AT 130 RYERSON CAUSING IT TO SHIFT AND EXPSORUE 2 WALL AT 126 RYERSON STREET OWNERS TO HIRE NYSPE TO SUBMIT REPORT TO ERTINSPECTIONS@BUILDINGS.NYC GOVWITHIN 72 HRS ADDRESSING ALL CONDITIONS W/PLANS,PHOTOS RECOMMENDING |