8 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jul 26, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jul 26, 2007 | V*-DOB VIOLATION - DISMISSED | Z-ZONING NONE | Z-ZONING NONE |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO ADEQUATELY SUPPORT ADJOINING GROUND AND OR STRUCTURES AFFECTED BY EXCAVATION. NOTED WORK ONGOING UNDER PERMIT #302278130 HAS EXCAVATED APPROX. 25' IN DEPTH FOR APPROX. 45' LENGTH WITHOUT PROTECTION FOR PEDESTRIAN SIDEWALK ON 66 ST. REMEDY: STOP ALL WORK CALL 718-802-3685 FOR APPT. TO RESCIND SWO |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO ADEQUATELY PROTECT THE SIDES OF EXCAVATION CARRIED TO A DEPTH GREATER THAN 5FT. NOTED: WORK UNDER PERMIT# 302278130 HAS EXCAVATED APPROX. 45' AREA 25' DEEP WITHOUT SHORING REMEDY: STOP ALL WORK. PROVIDE PROTECTION. MAKE SAFE. BACK FILL SITE AT 45 DEGREE ANGLE OF REPOSE CALL 718-802-3685 FOR APPT |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO PROVIDE 3'6" GUARD RAIL OR SOLID ENCLOSURE AROUND OPEN AND ACCESSIBLE SIDES OF EXCAVATION FOR WORK ONGOING UNDER PERMIT#302278130 . AT THE TIME OF INSPECTION EXCAVATION APPROX 20' DEEP REMEDY: STOP ALL WORK. PROVIDE GUARD RAILS OR ENCLOSURE CALL 718-802-3 685 FOR APPT. TO RESCIND SWO |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | SHORING DETAIL DOES NOT CONFORM TO APPROVED PLAN FOR WORK ONGOING UNDER PERMIT# 302368088 WHICH SHOWS 8' SPACING BETWEEN SOLDIER PILES, LOCATION OF LAGGING CONTRARY REMEDY: AMEND PLAN. STOP ALL WORK. CALL 718-802-3685 FOR APPT. TO RESCIND SWO |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STRUCTURAL PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE AND OF SUFFICIENT CLARITY TO INDICATE ENTIRE NATURE AND EXTENT OF PROPOSED SHORING. REMEDY: STOP ALL WORK. PROVIDE DETAILED DRAWING CALL 718-802- 3685 TO RESCIND SWO |
| Jul 11, 2007 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | DESIGNATED CONTROLLED INSPECTOR NOT ON SITE WHEN CONTRACTOR IS PERFORMING SHORING. EXCAVATION AT TIME OF INSPECTION APPROX. 20' DEEP FOR WORK ONGOING UNDER PERMIT#302278130 REMEDY: STOP ALL WORK. NOTIFY CONTROLLED INSPECTOR CALL 718-802-3685 FOR APPT. TO RESCIND SWO |