NYC Building Report

Brooklyn Clinton Hill

102 Ryerson Street, Brooklyn

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

22 records

Date Status Type Summary
Oct 22, 2026 V-DOB VIOLATION - ACTIVE IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL REMEDY- REMOVE APPROX. 50 LINEAR FEET OF THE EXISTING NON-COMPLIANT FENCE AND REPLACE IT WITH A CODE COMPLIANT CONSTRUCTION FENCE. FENCE TO BE REPLACED AT CURRENT LOCATION, FULL LOT WIDTH AT EXPOSURE 1, 20-FEET, PLUS TWO 15-FOOT END RETURNS ALONG THE EXPOSURE 2 AND 4 LOT LINES. TOTAL 50 LINEAR FENCE
Mar 28, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADDITIONAL INFORMATION.SHORED&BRACED UNDR IED 18028 PEREOR'S APPRVD MEANS&METHODS ON SK-01 THRU SK-06 DATED 1/19/24 W/FEU COMMENTS DATED 1/20/24.DAILY REPORTS BY EOR WERE REQ'D TO BE SUBMITTD.IMMEDIATELY COMPLY W/COMMISSIONER'S ORDER #343434 (032124FEU30201PN)DATED MARCH 21,2024.SUBMIT OUTSTANDNG PRO
Mar 21, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADDITIONAL INFORMATION.SHORED&BRACED UNDR IED 18028 PEREOR'S APPRVD MEANS&METHODS ON SK-01 THRU SK-06 DATED1/19/24 W/FEUCOMMENTS DATED 1/20/24.DAILY RPORTS BY EOR WERE REQ'D TO BE SUBMTTD.OF AL S&S DAILY DAILY RPORTS WHEN WRK TOOK PLACE
Feb 2, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WEATHRPRF INTEGRITY OF ADJOINGING BLDGS.BLDG UNDR ADDTNL SHORNG BY OWNERS PE W/DAILY RPORTS SUBMITTD TO FEU.BLDG VISIBLY LEANING TOWARDS EXP2&VACANT LOT@104 RYERSON STREET EVIDENCED BTY VERT CRCK.OWNR TO RTAIN NYSPE&GC REQ W/DOB TO IMMED WEATHERPRF ADJ 100 RYERSON ST BLDG PER BC 3309.WHERE WEATHERPRF INTEGRITY
Feb 2, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADDITIONAL INFO/MONITORNG.EXP2WALL PREV REMVD@1STFL TO ROOF & INADEQUATELY TEMPORARILY SHORED&INADEQUATELY WEATHERPRFD W/TARP BLDG UNDR ADDTNL SHORNG BY OWNRS IS PE W/DAILY RPORT SUBMITTD TO FEU.OWNR TO RTAIN LICENSD MONITORNG COMPANY/NYS PE TO INSTALL OPTICAL MONITORNG @EXP1,2,3&CRCK MONITORNG@EXP1 CRCKS@102 RYE
Feb 2, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EXP2 WALL PREVIOUSLY REMOVED@1STFL TO ROOF W/TEMP/INADEQUATE SHORNG BLDG UNDR ADDTNL SHORNG BY OWNER'S PE UNDR HOLD ON IED#18028 PER PE DAILY RPORTS SUBMITTD TO DOB BTWN 1/23/24 & 2/2/24.COMPLY WITH CODE FILE DWGS TO LEGALIZE ALL WRK TO MATCH EXISTNG CONDITIONS.OBTAIN PRMT IMMEDIATELY
Dec 19, 2023 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL EXTEND/REINFORCE EXISTING SHORING OR INSTALL NEW LINE OF SHORING TO PROVIDE CONTINUOUS SHORING ALONG FULL BLDG DEPTH W/ SHORING DIRECTLY IN LINE VERTICALLY. INSTALL A MIN OF 1 ADD SHORING LINE FULL HT FROM CELLAR TO ROOF & FULL BLDG DEPTH W/ LATERAL CROSS BRACING TYING THE(2) SHORING LINES TOGS. SPACE SHORING LINES MIN 4 FT HORIZ. TIE BACK EXP 1
Dec 13, 2023 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER PERMIT #B08024318 ON 12/12/23 SUSPENSION OF PERMIT, INTENT TO REVOKE.
Dec 11, 2023 V*-DOB VIOLATION - DISMISSED EGNCY-EMERGENCY NONE FULLY DEMOLISH THE BUILDING. GRADE AND FENCE SITE
Dec 11, 2023 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL IMMEDIATELY INSTALL A MINIMUM 1 LINE OF SHORING NEAR THE CENTER OF THE BLDG FOR THE FULL HEIGHT FROM CEL. TO UNDERSIDE OF ROOF&FULL BLDG DEPTH W/LATERAL CROSS BRACING TYING THE EXISTING SHORING TO THE NEW CENTER LINE SHORING. NEW SHORING TO BE SPACED MINI 6TH HORIZONTALLY FROM EXISTING SHORING LINES. TIE BACK EXP.1&2 TO BACK TO STRUCTURE
Aug 4, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL ADDITIONAL INFORMATION:3STORY+B WOOD FRAME W/EXP1&2 WALLREPAIRS ONGOING UNDER PERMIT ##B08024318-I10GC.SPECIAL INSPECTOR ISBRIAN FLYNN PE.WORK HAS BEEN ONGOING UNDER MULT SWO'S PER DOB INSP.SPECIAL INSPCTR OF OF RECRD, BRIAN FLYNN, PE SHALL PRVDE ALL INSPCTN DATES&SGND&SEALED INSPECTN RPORTS W/PHOTOS SUMMARIZNG
Aug 1, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNLAWFULLY CONTINUED OF WORK WHILE ON NOTICE OF A STOP WORK ORDER. AT TIME OF INSPECTION, APPROXIMATELY 4 CONSTRUCTION WORKERS PERFORMING WORK AND/OR ERECTING CMU MASONRY WALL AT EXPOSURE #2, AND OTHER MISCELLANEOUS WORKS, CONTRARY TO STOP WORK ORDER #039058769Y.
Aug 1, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL UNLAWFULLY CONTINUED OF WORK WHILE ON NOTICE OF A STOP WORK ORDER. AT TIME OF INSPECTION, APPROXIMATELY 4 CONSTRUCTION WORKERS PERFORMING WORK AND/OR ERECTING CMU MASONRY WALL AT EXPOSURE #2, AND OTHER MISCELLANEOUS WORKS, CONTRARY TO STOP WORK ORDER #039058769Y.
Jan 6, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMER WORK ORDER.EXP2 WALL BULGING OUT&COMPROMISED.EXP1 WALL CRCKD W/ STUCCO SPALLING.BLDG TEMP SHORED @ INTERIOR&AT FRONT YARD W/DIAGNL BRACES.FRNT YRD OPEN&A DANGER TO THE PUBLIC.OWNR TO RETAIN GC REG W/ DOB TO INSTALL TIGHT BOARD FENCE TO SECURE FRNT YARD.START WRK BY 1/9/23 & CONT WORK DAILY
Jan 3, 2023 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. ST TIME OF INSPECTION IT WAS OBSERVED THAT THE EXPOSURE 2 EXTERIOR STUCCO WALL WAS IN A STATE OF DISREPAIR WITH BULGING AND MULTIPLE STRUCTURAL CRACKS, ALONG WITH BULGING AND CRACKING OF THE EXPOSURE 1 FACADE
Mar 16, 2022 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Mar 9, 2022 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL IMMEDIATELY INSTALL A MIN OF TWO LINES OF SHORING WITH LATERAL.CROSS BRACING BETWEEN THE 2 LINES ALONG THE FULL LENGTH OF THE EXP 2 WALLS & EXTENDING THE FULL HEIGHT OFTHE BUILDING FROM CELLAR SLAB TO UNDERSIDE OF THE ROOF JOISTS. TIE JOISTS TO EXP 2 WALL AT 1ST,2ND, 3RD, AND ROOF LEVELS. SHORING AND BRACING TO BE DESIGNED BY A NYS PE
Mar 9, 2022 V-DOB VIOLATION - ACTIVE UB-UNSAFE BUILDINGS NONE UB-UNSAFE BUILDINGS NONE
Feb 28, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN A SAFE CONDITION. 102 RYERSON ST BLDG HAS THE FOLLOWING DAMAGE-VERT CRACK AT EXP 1/2 CORNER FROM GRADE UP TO 1FL WINDOW LEVEL, HORIZONTAL CRACK AT EXP 1 STUCCO ALONG 1FL, HORIZONTAL CRACK & BULGE AT EXP 2 WALL ALONG 2FL LEVEL. REMEDY: OWNER TO RETAIN NYSPE TO EVAL ENTIRE BLDG & PREPARE/FILE REPAIR DWGS. REPAIR UNDER PERMIT BY 3/14/22
Feb 25, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL AT EXPOSURE #2 FACADE WALL IN DISREPAIR CONDITION BULGING AND HAS VERTICAL CRACK. AT THE CORNER OF EXPOSURE 1 FACADE WALL BULGING AND HAS VERTICAL CRACK.
Jan 14, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. BUILDING LOBBY INTERIOR WALL AT EXPOSURE # 2 IN SEVERE STATE OF DISREPAIR WITH DEFLECTION, MULTIPLE CRACKS, MISSING PLASTER AND EXPOSED BRICK.
Apr 29, 1992 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL