Bronx Hunts Point
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
12 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jan 13, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTC W/COMMISSIONER'S ORDER-VIO#121125PI20202HZ CONTROL#348052 DATED 12/11/25 REQUIRING OWNER TO SUBMIT A CORRECTIVE ACTION PLAN BY 01/11/26.AS OF 01/13/26 THE REQ'D CAP WAS NOT REC'D. IMMED COMPLY WITH COMMISSIONER'S ORDER VIO#121125PI20202HZ CONTROL#348052 |
| Dec 11, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMERGENCY WORK ORDER-OBSVD IMMED HAZ CONITIONS @ EXP4 BY CORNER OF EXP1(FAILE ST)SPALLED,BULGING/LOOSE STUCCO/PARGING @ ABOUT 5TH FLOOR LEVEL. COMPLY W/CODE IMMED RETAINA DOB REG GC TO INSTALL OVERHEAD PROTECTION/SIDEWALK SHED TO PROTECT PUBLIC/TEMANTS. PROVIDE APPROX 20 LINEAR FEET OF SH ALONG EXP4 BY THE EXP1/4 CORNER |
| Dec 11, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | CORRECTIVE ACTION PLAN REC'D-OBSVD HAZ COND OF CRACKED & DISLODGE CONCRETE STUCCO @ EXP4 RIGHT SIDE OF BLDG. PARAPET WALL IN DISREPAIR @ VARIOUS LOCATIONS W/STEP CRACKS,LEANING WALL,DISLODGE MORTAR. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING W/DOB&NYS-ED TO EVAL THE ENTIRE BLDG & TO SUBMIT A CORRECTIVE ACTION PLAN BY 01/11/26 |
| Dec 11, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD PARAPET WALLS CAP STONE WALLS BRICKS&MORTAR IN DISREPAIR, ALSO STEP CRACKS&LEANING INWARD AT VARIOUS LOCATIONS.AN ANNUAL PARAPET WALL OBSERVATION REPORT IS REQ'D TO BE COMPLETED STARTING IN JAN 2024.SUBMIT ANNUAL PARAPET OBSERVATION REPORT FOR YEAR 2024&2025 T/BE REC'S BY DOB NO LATER THAN 12/29/2025 |
| Dec 15, 2022 | V*-DOB VIOLATION - DISMISSED | RWNRF-RETAINING WALL NONE | FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09 |
| Aug 2, 2022 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Apr 6, 2018 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT |
| Oct 1, 2015 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT |
| Jan 1, 2012 | V-DOB VIOLATION - ACTIVE | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Jan 3, 2008 | V-DOB VIOLATION - ACTIVE | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 7, 2000 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Nov 18, 1994 | VH-VIOLATION HAZARDOUS - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |