DOB violations
Department of Buildings violations attached to this BIN or tax lot.
18 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 8, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED SPALLED/SPALLING BRICK WORK IN MULTIPLE LOCATIONS ON EXPOSURES 1 AND 4 ALSO DAMAGED/MISSING, MORTAR JOINTS. REMEDY: REPAIR AND/OR REPLACE |
| Mar 31, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED @ EXP1 1FL CRACK, MISSING BRICK, OPEN JOINTS & 2FL VIEW MULTIPLE DEFECT THROUGH NETTINGS. EXPOSURE 4 OBSERVED SPALLING, DAMAGED JOINT & FAILED STUCCO. REMEDY: REPAIR AND/OR REPLACE |
| Oct 15, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED AT EXP 1 S.ELEV ERODED BRICKS & DETERIORATED MORTAR JOINTS, CRACKS, SPALLED BRICKS & FALLEN BRICK ON THE FLOOR. AT EXP 4 E.ELVE CRACKED STUCC, SPALLED BRICKS & DETERIORATED MORTAR JOINTS WERE OBSERVED. REMEDY: REPAIR AND OR REPLACE |
| Oct 15, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: AT TIME OF INSPECTI IT WAS OBSERVED @ EXPOSURE 1 (S.ELEV)ERODED BRICKS & DETERIORATED MORTAR JOINTS, CRACKS, SPALLED BRICKS & FALLEN BRICK ON THE FLOOR. AT EXP 4 (E.ELEV) CRACKED STUCCO, SPALLED BRICKS & DETERIORATED MORTAR JOINTS WERE OBSERVED. REMEDY: REPAIR AND/OR REPLACE |
| Sep 23, 2024 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 7, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG CODE COMPLIANCE. AT TIME OF INSPECTION I OBSERVED ON EXP #1 SOUTH ELEVATION & EXP #4 EAST ELEVATION; ERODED, DISINTEGRATING BRICKS & MORTAR JOINTS @ PARAPET. PARAPET ON EXPOSURE #1 WERE LOOSE DISLODGED BRICKS AND MORTAR JOINTS. REMEDY: REPLACE AND/OR REPLACE ALL DAMAGED MASONRY WORK ON ALL ELEVATIONS |
| Oct 4, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS NOTED BUILDING HAS DEFECTIVE CEMENTESOUS COATING DAMAGED MORTAR JOINTS AND SPALLING BRICKS ON EXPOSURE#1&4 REMEDY:MAINTAIN BUILDING COMPLY WITH CODE REPAIR DAMAGED FACADE |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION |
| Apr 25, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION |
| Nov 8, 2019 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT |
| Oct 1, 2015 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT |
| Mar 9, 2001 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jan 23, 2001 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| May 4, 1998 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jun 9, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |