Bronx Melrose
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
26 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Nov 14, 2025 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| Sep 23, 2024 | V-DOB VIOLATION - ACTIVE | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 11, 2024 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TI ME OF INSPECTION I OBSERVED ON EXP4 NORTH ELEV,DAMAGED AND MISSING MOR TAR JOINTS AND BRICKS AT PARAPET AND 3RD FL LEVELS.REMEDY:REPAIR AND/O R REPLACE DAMAGED BRICKS AND MORTAR JOINTS |
| Jun 15, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED BROKE N STONES,BULGING BRICK WORK,DAMAGED MORTAR JOINTS AT EXP1.DAMAGED TERR ACOTTA,STEP CRACKS,CRACKED STUCCO AT EXP3.DEFECTIVE WINDOW FRAMES AT A LL EXPOSURES.DETERIORATED MORTAR JOINTS AT EXP4.REMEDY:REPAIR AND/OR R EPLACE |
| Feb 22, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE&APPURTENANCES.PREVIOUS DEFECT.COND.STILL REMAIN.BROKEN STONES BULGING BRICKWORK,AND DAMAGED MORTAR JOINTS ON EXP#1 E.ELEV.DAMAGED TERRA COTTA,STEP CRACKS,&CRACKED STUCCO ON EXP#3W.ELEV.DETERIORATED MORTAR.JOINTS ON EXP#4 N.ELEV DEFECT.ON EXP#4 NO.ELEV.DEFECTIV WINDOW FRAMES ON ALL EXPOSURE 3 |
| Nov 21, 2022 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM EXTERIOR BLDG FACADE & APPURTENANCES,BROKEN STONES,BULGING BRICK WORK, & DAMAGED MORTAR JOINTS ON EXP1 EAST ELEV,DAMAGED TERRA COTTA, STEP CRACKS & CRACKED STUCCO ON EXP3 WEST ELEV.DETERIORATED MORTAR JOINTS ON EXP4 NORTH ELEV. DEFECTOVE WINDOW FRAMES ON ALL EXPOSURES REMEDY:MAINTAIN EXTR BLDG FACADE,REPAIR DAMAGED FACADE AS PER 1RCNY |
| Aug 27, 2022 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM BLDG EXTERIOR WALL FACADE AND APPURTENANCES. OBSERVED DEFECTED/ DETERIORATION OF BLDG FACADE AT ALL EXPOSURES. STEP CRACK, BROKEN STONES, OPEN JOINTS AND A/C SUPPORT INADEQUATE ALSO SAMAGE FRAMES AND MISSING GLASS PANE. REMEDY: MAINTAIN BUILDING IN CODE COMPLIANT |
| May 9, 2022 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FTM BLDGING IN CODE COMPLIANT. AT TIME OF INSPECTION OBSERVED DEFECTED CONDITIONS AT ALL EXPOSURES, CRACKS, STEP CRACKS, BROKEN STONES, OPEN JOINTS AND A/C SUPPORT INADEQUATE ALSO SAMAGED WINDOW/ FRAMES. REMEDY: MAINTAIN BUILDING IN CODE COMPLIANT |
| Apr 14, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 6, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| May 2, 2017 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Feb 16, 2017 | V*-DOB VIOLATION - DISMISSED | EARCX-FAILURE TO SUBMIT EER NONE | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2016 |
| Aug 2, 2016 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Jun 2, 2016 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Feb 2, 2016 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Nov 2, 2015 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Aug 2, 2015 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| May 2, 2015 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| May 1, 2014 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Jan 6, 2006 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 31, 2005 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 13, 2004 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 19, 2003 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 26, 2002 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Oct 3, 1990 | V*-DOB VIOLATION - DISMISSED | ES-ELECTRIC SIGNS NONE | ES-ELECTRIC SIGNS NONE |
| Dec 7, 1989 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |