Bronx Mott Haven-Port Morris
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 2-02295-0067), so they can include other buildings on the same lot.
291 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Oct 5, 2026 | C | NOV SENT OUT | 13D | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 5, 2026 | C | NOV SENT OUT | 13E | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13E, 13th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 5, 2026 | C | NOV SENT OUT | 13D | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Oct 5, 2026 | B | NOV SENT OUT | 13E | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL AND BUZZER INTERCOM SYSTEM FROM BUILDING FRONT TO PANEL AT SOUTH WALL IN THE FOYER LOCATED AT APT 13E, 13th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING INSIDE THE CLOSET AT EAST IN THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING INSIDE THE CLOSET AT EAST IN THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | A | NOTICE OF ISSUANCE SENT TO TENANT | 4D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING INSIDE THE CLOSET AT EAST IN THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING INSIDE THE CLOSET AT NORTH IN THE FOYER LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING INSIDE THE CLOSET AT NORTH IN THE FOYER LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | C | NOTICE OF ISSUANCE SENT TO TENANT | 4D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT CEILING IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | C | NOTICE OF ISSUANCE SENT TO TENANT | 4D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 22, 2026 | B | NOV SENT OUT | 4D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 17, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR |
| Sep 8, 2026 | C | NOV SENT OUT | 4E | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN UNDER WASH BASIN IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .... IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN THE DRAIN PIPE AT BATH TUB IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE THE CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | B | NOV SENT OUT | 3B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE THE CEILING IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | A | NOV SENT OUT | 4E | § 27-2005 HMC: REFIT ALL CLOSET DOORS IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Sep 8, 2026 | C | NOTICE OF ISSUANCE SENT TO TENANT | 13C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 13C, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Sep 8, 2026 | C | NOTICE OF ISSUANCE SENT TO TENANT | 13C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 13C, 13th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Aug 18, 2026 | C | NOV SENT OUT | 11A | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET INOPERABLE TOILET BOWL. IN THE BATHROOM LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM NORTH AT EAST |
| Aug 18, 2026 | C | VIOLATION CLOSED | 13D | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING 130 DEGREES FAHRENHAIT AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Jul 1, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE DOOR AT COMPACTOR CLOSET, 13th STORY |
| Jun 6, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLIES AT ENTRANCE DOOR , 1st STORY |
| Jun 6, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET TO ENTRANCE DOOR , 1st STORY |
| May 27, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT STREET TO VESTIBULE , 1st STORY |
| May 27, 2026 | A | VIOLATION CLOSED | Not available | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE |
| May 27, 2026 | A | NOT COMPLIED WITH | Not available | §27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING AT PUBLIC HALL, 1st STORY |
| May 13, 2026 | C | VIOLATION CLOSED | 13B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13B, 13th STORY, 1st APARTMENT FROM NORTH AT EAST |
| May 13, 2026 | A | NOT COMPLIED WITH | 11A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS, CEILING AND TRIMS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 13, 2026 | B | NOT COMPLIED WITH | 11A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 13, 2026 | B | NOT COMPLIED WITH | 11A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 13, 2026 | B | NOT COMPLIED WITH | 11A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASECABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 13, 2026 | B | NOT COMPLIED WITH | 11A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 11A, 11th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| May 13, 2026 | C | DEFECT LETTER ISSUED | 13D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| May 13, 2026 | C | VIOLATION DISMISSED | 13D | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES FAHRENHEIT AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 30, 2026 | B | VIOLATION CLOSED | 3D | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 30, 2026 | B | VIOLATION CLOSED | 3D | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| Mar 30, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 10th STORY |
| Mar 7, 2026 | B | VIOLATION CLOSED | 13D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT WINDOW STOOL AND WINDOW FRAME IN THE 1st ROOM FROM NORTH LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18691490 ISSUED 07-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b). |
| Mar 7, 2026 | A | VIOLATION CLOSED | 13D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WINDOW STOOL AND WINDOW FRAME. IN THE 1st ROOM FROM NORTH LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 7, 2026 | B | VIOLATION CLOSED | 13D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WINDOW STOOL AND WINDOW FRAME IN THE 1st ROOM FROM NORTH LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Mar 7, 2026 | A | VIOLATION CLOSED | 13D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT WINDOW STOOL AND WINDOW FRAME IN THE 1st ROOM FROM NORTH LOCATED AT APT 13D, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Feb 25, 2026 | C | NOT COMPLIED WITH | Not available | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM |