Bronx Mott Haven-Port Morris
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
22 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 4, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTC WITH COMMISSIONER'S ORDER CONTROL#370479 VIO#042926PI20101SB DATED 04/29/26 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 05/29/26 AS OF 06/04/26 THE REQ'D CAP WAS NOT REC'D. IMMED COMPLY WITH COMMISSIONER'S ORDER CONTROL#370479 VIO#042926PI20101SB |
| Apr 29, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | CORRECTION ACTION PLAN REQ'D-OBSVD BULGING MASONRY NEAR PARAPET.@ EXP4 OBSVD SEVERAL SPALLING WINDOW SILLS & CRACKS IN BRICKS @ 1FL. AT BOTH EXP1/2 & 1/4 CORNERS OBSVD MISSING MORTAR JOINTS. OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENTIRE BLDG AND TO SUBMIT A CORRECTIVE ACTION PLAN |
| Feb 25, 2026 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | PROVIDE APPROXIMATELY 47 LINEAR FEET OF SIDEWALK SHED ALONG THE ENTIRE FRONT OF EXPOSURE #1 THE SIDEWALK SHED SHALL BE INSTALLED TIGHT BACK TO THE BUILDING AND EXTEND 5 FEET PAST THE BUILDING ON BOTH SIDE |
| Jul 28, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | DURING THE INSPECTION, LARGE GAPS WERE OBSERVED BETWEEN THE BRICKS, INDICATING POTENTIAL STRUCTURAL CONCERNS. ADDITIONALLY, THERE WAS EXPOSURE TO ELEMENTS THAT VIOLATE MAINTENANCE STANDARDS. REQUESTING A PE REPORT TO BE SUBMITTED WITHIN ONE WEEK |
| Jun 20, 2018 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jun 15, 2018 | VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE | B-BOILER BOILER OPTIONAL | B-BOILER BOILER OPTIONAL |
| Jun 15, 2018 | VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE | B-BOILER BOILER OPTIONAL | B-BOILER BOILER OPTIONAL |
| May 30, 2018 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 1, 2009 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 3, 2008 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 19, 2007 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Dec 18, 2006 | V-DOB VIOLATION - ACTIVE | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL |
| Jan 6, 2006 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jan 31, 2005 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Mar 19, 2003 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 4, 1998 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Sep 16, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Feb 10, 1997 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Jul 17, 1995 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | C-CONSTRUCTION OTHER OPTIONAL |
| Jun 9, 1994 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| May 17, 1993 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |