Bronx Tremont
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
12 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 27, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.APPRX 6FT WIDE OPENING THROUGH THE 1STFL EXP2 PARTY WALL WAS MADE TO EXTEND THE COMMERCIAL SPACE INTO THE 443 EAST 180ST 1STFL.FIRE SEPARATION BTWN 443&447 HAS BEEN COMPROMISED.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS W/DOB PRM RPAIR BLDG UNDR PRMT STRTNG BY 7/22/24&CMPLTD/SGND OFF 8/30 |
| Jun 27, 2024 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.EXP3WOOD FRAMEWALL WAS PRTLLY DTACHD&OPEN@1ST&2NDFLRS.TEMP SHEATHNG INSTALLD@EXP3WAS INADEQUATE&AT RISK OF COLLAPSE.3RDFL@REAR SLOPNG TWARDS CENTR BLDG OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS.BLDG TO BE PERM RPAIRD UNDR PRMT STRTNG BY 7/22/24&CMPLTD/SGND OFF 8/30/24 |
| Jun 27, 2024 | V-DOB VIOLATION - ACTIVE | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Jun 27, 2024 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | OBSERVED SHARED PARTY WALL OF 443 AT EXP 4 WITH 447 EAST 180 ST BUILDING WAS COMBINED WITH THE 443 BUILDING WITH APPROXIMATLEY A 6 FEET WIDE OPENING THROUGH THE PARTY WALL. THE FIRE SEPARATION BETWEEN THE 443 AND 447 BUILDINGS WAS COMPROMISED. |
| Jun 27, 2024 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO MAINTAIN BUILDING. OBSERVED THE EXP 3 WALL AT 433 WAS PARTIALLY COLLAPSED AND OPEN AT THE 1ST FLOOR AND 2ND FLOOR. WITH THE POTENTIAL OF FURTHER COLLAPSE. |
| Dec 4, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | VIO23-50307 |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 30, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION |
| Jun 20, 2023 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION |
| Nov 8, 2019 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT |
| Jan 6, 2006 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |