Bronx Kingsbridge Heights-Van Cortlandt Village
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
27 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Jun 30, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #022025CFA08 02DD REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY PE/RA AND SUBMIT A REPORT TO FACADES VIA EMAIL BY 3/7/25.AS OF 6/30/26 NO HANDS ON INSPECTION REPORT SUBMITTED TO FACADES UNIT.REMEDY:COMPLY WITH DOB VIOLATION #022025CFA0802DD IMMEDIATELY |
| Feb 20, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM FACADE & APPURT DUE TO CRACKED/SPALLING BRICK & MORTAR JOINTS MULTI LOCAT & CRACKED BULGIN BRICK EXP1 EAST 5 FL WINDOW.REMDY:RETAIN A NYS RDP WITH QEWI CERTIFICATN TO INSPECT/EVALUATE 100% HANDS ON THE MASONRY FACADE TO DETERMINE CODE COMPLIANCE & ENSURE STABILITY.INSTALL PUBLIC PROTECTN & SUBMIT REPORT TO FACADE@BUILDING.N.G BY 3/7/25 |
| Feb 20, 2025 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EWO DUE TO CRACKED/SPALLING BRICK MULTI LOCAT, CRACKED/BULGING BRICK, BRICK PUSHING OFF WINDOW OF 5TH FL WINDOW EXP 1 EAST NORTHEAST END REMDY:IMMEDTLY TAKE/PROVIDE ADEQUATE SAFETY MEAS @ EXP 1 EAST (GOUVERN EUR AVE) & INSTALL PUBLIC PROTECTN. MAKE IMMEDIATE REPAIRS TO DEFECTIV FACADE UNDR THE SUPERV OF NYS LP & FILE AN UNSAFE FISP REPORT |
| May 2, 2019 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Apr 4, 2019 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 9, 2018 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Apr 24, 2017 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 1, 2016 | V*-DOB VIOLATION - DISMISSED | EVCAT5-NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST ELEVATORREQUIRED | FAILURE TO PERFORM CATEGORY 5 INSPECTION |
| Apr 8, 2016 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Sep 15, 2015 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 15, 2014 | V*-DOB VIOLATION - DISMISSED | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT |
| Jul 15, 2013 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| May 3, 2012 | V*-DOB VIOLATION - DISMISSED | BENCH-FAILURE TO BENCHMARK NONE | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Feb 29, 2012 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Mar 24, 2011 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 27, 2009 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jun 6, 2008 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Aug 1, 2007 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Nov 16, 2006 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 28, 2005 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Oct 1, 2005 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Feb 24, 2004 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | E-ELEVATOR ELEVATORREQUIRED |
| Jan 13, 1997 | V*-DOB VIOLATION - DISMISSED | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Jan 13, 1997 | V-DOB VIOLATION - ACTIVE | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL | LL1081-LOCAL LAW 10/81 - ELEVATOR ELEVATOROPTIONAL |
| Aug 29, 1995 | V*-DOB VIOLATION - DISMISSED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED |
| Aug 20, 1990 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | 73 FIVE YEAR TEST AN FILE ELV#3 |
| Apr 19, 1990 | V*-DOB VIOLATION - Resolved | E-ELEVATOR ELEVATORREQUIRED | #18-SECURE KEEPERS-#35-PROVIDE ACCESS TO MOTOR ROOM & OVERHEAD- #40-5-YEAR TEST-#55-PIT & CAR TOP |