| Sep 1, 2021 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL |
| Sep 1, 2021 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL |
| Sep 1, 2021 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| Sep 1, 2021 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL |
| Jul 20, 2021 | A | VIOLATION CLOSED | Not available | § 27-2021 ADM CODE PROVIDE PLACE WITHIN THE BUILDING FOR THE STORAGE OF WASTE RECEPTACLES AND DISINFECT SAME REGULARLY. |
| Jun 7, 2021 | B | NOT COMPLIED WITH | 6B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL /BUZZER FROM VESTIBULE TO PRIVATE HALL LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM WEST AT NORTH |
| Apr 2, 2021 | A | VIOLATION DISMISSED | Not available | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| Dec 13, 2019 | B | VIOLATION CLOSED | 5C | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ FT ON WINDOW FRAME AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 13502789 ISSUED 13-DEC-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Dec 13, 2019 | A | VIOLATION CLOSED | 5C | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ FT ON WINDOW FRAME AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| Dec 5, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT STACK AT REAR YARD |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. AT PUBLIC HALL |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL |
| Dec 5, 2019 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .. AT PUBLIC HALL |
| Sep 10, 2019 | B | VIOLATION CLOSED | 6B | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). (MISSING) LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Jun 16, 2019 | A | VIOLATION DISMISSED | 6B | § 27-2005 ADM CODE REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | C | VIOLATION CLOSED | 6B | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION DISMISSED | 6B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT CERAMIC WALL TILES AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION CLOSED | 6B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 5 SQ. FT. OF MOLD AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION DISMISSED | 6B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT WEST WALL IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION CLOSED | 6B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 3 SQ. FT. OF MOLD AT WEST WALL IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION DISMISSED | 6B | § 27-2005 ADM CODE REFIT THE WINDOW LOWER SASH IN THE 2nd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | A | VIOLATION CLOSED | 6B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPTOX. 8 SQ. FT. OF MOLD AT EAST AND SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Jun 16, 2019 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 6B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND BUZZER SYSTEM IN THE ENTRANCE LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM NORTH AT EAST |
| Apr 19, 2018 | C | VIOLATION CLOSED | 1D | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ALL CEILING LIGHT FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Apr 19, 2018 | B | VIOLATION DISMISSED | 1D | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Apr 19, 2018 | B | VIOLATION DISMISSED | 1D | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Apr 19, 2018 | C | VIOLATION CLOSED | 1D | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Jul 27, 2017 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY |
| Jul 27, 2017 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| Jul 27, 2017 | A | VIOLATION CLOSED | Not available | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY |
| Jul 27, 2017 | A | VIOLATION CLOSED | Not available | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY |
| Jul 27, 2017 | A | VIOLATION CLOSED | Not available | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| Jul 27, 2017 | C | VIOLATION CLOSED | Not available | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY |
| Feb 9, 2016 | A | VIOLATION CLOSED | Not available | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| May 23, 2015 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFRIGERATOR WITH DOOR INTACT FRONT OF APARTMENT#1D AT PUBLIC HALL, 1st STORY |
| Feb 22, 2015 | C | VIOLATION CLOSED | 6B | SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Feb 22, 2015 | C | VIOLATION CLOSED | 6B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING 130 F IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Jun 26, 2014 | A | VIOLATION CLOSED | Not available | SECTION 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT LOBBY |
| Jun 26, 2014 | A | VIOLATION CLOSED | Not available | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT LOBBY |
| Jun 26, 2014 | A | VIOLATION CLOSED | Not available | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT LOBBY |
| Jun 26, 2014 | A | VIOLATION CLOSED | Not available | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ... AT LOBBY |
| Jun 26, 2014 | A | VIOLATION CLOSED | Not available | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT LOBBY |