| Date | Status | Type | Summary |
|---|---|---|---|
| Feb 17, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | ADDITIONAL INFORMATION.BASED ON THE FINDINGS OF D.013 INSPECTION ON 2-17-23.SOME NON-CONFORMANCES OF CONSTRUCTION ITEMS AT THE SITE PROVIDE STRUCTURAL DRAWING SHOWN DETAIL AND NEW DETAILS&EXISTING CONDITIONS & MODIFICATION |
| Feb 17, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.CONFORM OR AMEND DOCUMENTS |
| Jan 19, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTC W/COMMISSIONER'S ORDER 34155(010423FEU20801ZT)DATED 1/4/23 REQ OWNR TO STRT BLDG RPAIRS UNDR PRMT FOR THE UNSTBLE GARAGE OF 1/19/23, THERE ARE NO JOBS FILED IN BIS OR DOBNOW TO REPAIR BLDG.IMMED COMPLY W/ COMMISSIONER'S ORDER #341155 (010423FEU20801ZT) TO REPAIR THE BLDG UNDR PERMIT |
| Jan 19, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTC W/COMMISSIONER |
| Jan 9, 2023 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | BASED ON THE FINDINGS OF DOB INVESTIGATION AND ISNPECTION ON 01/04/23 DOB ENG'R OBSERVED SOME NON CONFORMANCE CONSTRUCTION ITEMS AT SITE REMEDY: OWNER TO RETAIN AN NYSPE TO VISIT THE SITE AND SUBMIT THE FOLLOWING: STRUCT STAB REPORT OF DOC FRAMING,STRUCT DWGS DOCUMENTING EXISTING CONDITIONS & ANY MODIFICATION REQ'D BASED ON UNDOC WOOD FRAME |
| Jan 4, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | EMER WORK.EXP2,3,&4 WALL WERE UNBRACD DUE TO THE REMOVSL OF ROOF JOIST &ROOF DIAPHRAGM.THE RMAINDER PARAPET APPEARED TO BE LOOSE&CRCKD.THE MORTAR JOINT WAS MISSING.NEWLY INSTLLD BEAMS WERE NOT PROP SUP 1.BRACED ALL WALLS.2.FOR DEMO PARAPET.3.NYSPE TO PROV DTAILS&MEANS/ METHD TO DEMO TO FEU BY 1/5/23 4 NYSPE TO SPRVSE WORK |
| Jan 4, 2023 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | VACATE ORDER.DANGER OF STRCTRL FAILURE.2,3,4 WALLS WERE UNBRACED DUE TO REMVL OF ROOF JOISTS&ROOF DIAPHRAGM.REMAINDER PARAPET APPEARED TO BE LOOSE&CRCKD.EXP3 PARAPET IS IN STATE OF DISREPAIR.IMMEDATELY VACATE THE REAR YARD UNTIL CONDITION HAS BEEN REMEDIED UNDER PERMIT |
| Nov 7, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FAILURE TO COMPLY W/COMMISSIONER'S ORDER#341005(101222FEU20801ZT)DATED 10/12/2022 RQUIRNG OWNR TO STRT BLDG RPR UNDER PERMIT FOR THE STRCTRL WRK TYPE IN THIS BLDG.AS OF 11/7/2022,THERE ARE NO JOBS FILE IN BIS/ DOBNOW TO RPR THE BLDG.IMMED COMPLY W/COMMISSIONER'S ORDER#341005 (101222FEU20801ZT)TO REPAIR BLDG UNDER PERMIT |
| Oct 12, 2022 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | FTM-FL JOISTS CUT FOR PLMBNG WRK.TEMP WOOD WALL STUD INSTLLD FOR SUPPRT.STAIRS IMPROPRLY REINFRCD.STAIR STRINGR &END CONNCTN @GIRDR FRAMNG IMPROPR.WOOD JOIST &STUDS FULLY NOTCHED.FEW JOISTS ROTATED OWNER IMMED RTAIN NYSPE-EVAL ENTIRE BLDG &PREPARE/FILE RPR DWGS.RPR BLDG UNDR PRMT STRTNG 11/7/22.CMPLTD BY 12/5/22 |
| Mar 16, 2022 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 22, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 29, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 1, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 1, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Aug 4, 2021 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jun 9, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Mar 17, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Jan 6, 2021 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 24, 2020 | V%-DOB VIOLATION | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Sep 2, 2020 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Sep 2, 2020 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Feb 5, 2020 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Dec 11, 2019 | V-DOB VIOLATION - ACTIVE | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Oct 17, 2019 | V*-DOB VIOLATION - DISMISSED | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |