Bronx Kingsbridge Heights-Van Cortlandt Village
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 2-03256-0064), so they can include other buildings on the same lot.
515 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Nov 9, 2023 | C | VIOLATION DISMISSED | 2F | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ENTRANCE IN THE ENTRANCE LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | B | VIOLATION DISMISSED | 2F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | A | VIOLATION DISMISSED | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL AND NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | B | VIOLATION DISMISSED | 2F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | A | VIOLATION DISMISSED | 2F | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT DOOR IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | B | NOV SENT OUT | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Nov 9, 2023 | C | NOTICE OF ISSUANCE SENT TO TENANT | 2F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Oct 31, 2023 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPRX 6 SQ FT IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16346991 ISSUED 31-OCT-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Oct 31, 2023 | B | NOV SENT OUT | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 31, 2023 | A | VIOLATION CLOSED | 3D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPRX 6 SQ FT IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 31, 2023 | B | NOV SENT OUT | 3D | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT SOUTH IN THE 1st ROOM FROM EAST LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 16, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE , 1st STORY |
| Oct 16, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOORS AT PUBLIC HALL, 4th STORY |
| Oct 6, 2023 | A | NOV SENT OUT | 3E | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ...ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 6, 2023 | B | NOV SENT OUT | 3E | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ...ROTTED WOOD BASE SINK CABINET IN THE KITCHEN LOCATED AT APT 3E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Oct 3, 2023 | A | VIOLATION DISMISSED | 10F | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 10F, 6th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Oct 3, 2023 | B | DEFECT LETTER ISSUED | 10F | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 10F, 6th STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 25, 2023 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | 3D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 4 SQ FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16251201 ISSUED 25-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| Sep 25, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING REMOVABLE DEVICE (HOOK) AT FIRE DOOR AT PUBLIC HALL, 4th STORY |
| Sep 25, 2023 | A | NOV SENT OUT | 3D | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | A | NOV SENT OUT | 3D | § 27-2005 ADM CODE PROVIDE MECHANICAL STOPPER AT WASHBASIN IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | A | NOV SENT OUT | 3D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RECAULK AROUND THE BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | A | VIOLATION CLOSED | 3D | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 4 SQ FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | B | NOV SENT OUT | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | A | NOV SENT OUT | 3D | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE KITCHENETTE LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | C | VIOLATION CLOSED | 3D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHENETTE LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 25, 2023 | B | NOV SENT OUT | 3D | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER SPRING BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Aug 9, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 3rd STORY |
| Jul 8, 2023 | B | VIOLATION DISMISSED | 10C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH SPRING BALANCES AT FIRST WINDOW FROM EAST AT SOUTH IN THE KITCHEN LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2023 | B | VIOLATION DISMISSED | 10C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH SPRING BALANCE AT NORTH WALL IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2023 | C | NOTICE OF ISSUANCE SENT TO TENANT | 10C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jul 8, 2023 | C | NOTICE OF ISSUANCE SENT TO TENANT | 10C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 10C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 17, 2023 | B | VIOLATION DISMISSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DEFECTIVE CLOSER ARM DEVICE AT 2ND DOOR LEADING FROM STREET (BUILDING VESTIBULE DOOR) AT PUBLIC HALL, 1st STORY |
| Jun 17, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE 2ND DOOR LEADING FROM STREET (BUILDING VESTIBULE DOOR) AT PUBLIC HALL, 1st STORY |
| Jun 10, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR ( MISSING, BROKEN) NEAR APARTMENT 3E DOOR AT PUBLIC HALL, 5th STORY |
| Jun 10, 2023 | B | VIOLATION DISMISSED | 3E | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND AND ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | B | VIOLATION DISMISSED | 3E | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | B | VIOLATION DISMISSED | 3E | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | NOV SENT OUT | 3E | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS, CEILINGS, FRAMES, MOLDINGS, BASEBOARDS, CLOSETS AND DOORS. IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | VIOLATION DISMISSED | 3E | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | NOV SENT OUT | 3E | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | NOV SENT OUT | 3E | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | VIOLATION DISMISSED | 3E | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | B | VIOLATION DISMISSED | 3E | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | C | NOTICE OF ISSUANCE SENT TO TENANT | 3E | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | C | NOTICE OF ISSUANCE SENT TO TENANT | 3E | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Jun 10, 2023 | A | NOV SENT OUT | 3E | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD SINK BASIN AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| May 16, 2023 | C | VIOLATION CLOSED | Not available | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING VESTIBULE , 1st STORY |
| Apr 12, 2023 | B | NOV SENT OUT | 10A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHENETTE LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH |
| Apr 12, 2023 | B | NOV SENT OUT | 10A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd PRIVATE HALLWAY FROM NORTH LOCATED AT APT 10A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH |