Date Status Type Summary
Nov 26, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTC W/COMMISSIONER'S ORDER CONTROL#347947 VIO#102325PI20701HZ DATED 10/23/2025 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 11/06/2025. AS OF TODAY 11/26/2025 A CAP WAS NOT REC'D. IMMED COMPLY W/COMMISSIONER'S ORDER CONTROL#347947 VIO#102325PI20701HZ TO PROVIDE A CORRECTIVE ACTION PLAN
Nov 6, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL EMERGENCY WORK ORDER-IMMED HAZ CONDITION THE BLDG PARAPET @ THE EXP4 INNER COURT HAS BULGED INWARD,CRACKED,LEANING,UNSTABLE & AT RISK OF COLLAPSE.SOME OF THE PARAPETS ALONG EXP1 HAD CRACKED. OWNER TO IMMED HIRE NYSPE&DOB REG GC TO INSTALL S/W SHED @ EXP1(DAVIDSON AVE)FULL WIDTH APPROX 220 LINEAR FT
Oct 23, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN CODE COMPLIANT MANNER-OBSVD 2 AREAS IN DISREPAIR-MORTAR CRACKS CASING DISLODGEMENT OF BRICKS & LEANING CORNER ONTO S/W OVER FORDHAM RD & LEFT SIDE OF BLDG ON DAVIDSON AVE-PARAPET WALL IN DISRPR ANNUAL PARAPET OBSVER REPORT IS REQ'D T/BE COMPL ANNUALLY START 1/2024 SUBMIT ANNUAL OBSVER REPORT FOR YEAR 2024 T/BE RE'D BY DOB 11/06/25
Oct 23, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL CORRECTIVE ACTION PLAN REQ'D-OBSVD MORTAR VERT CRACK AT EXP4 FACING FORDHAM RD CREATING BRICK DISLODGEMENT,@ EXP1 FACING DAVIDSON AVE LEFT CORNER MORTAR AROUND BRICKS DISLDGED & DAMAGED BRICK. OWNER TO IMMED RETAIN REG DESIGN PROF IN GOOD STANDING W/DOB&NYS-ED TO EVAL ENTIRE BLDG & SUBMIT A CORRECTIVE ACTION PLAN BY 11/06/25
Apr 22, 2023 V-DOB VIOLATION - ACTIVE EARCX-FAILURE TO SUBMIT EER NONE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2022
Oct 1, 2015 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Dec 13, 2011 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Dec 13, 2011 V*-DOB VIOLATION - DISMISSED LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Feb 10, 1997 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Aug 29, 1995 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jun 9, 1994 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jan 25, 1994 V*-DOB VIOLATION - DISMISSED ES-ELECTRIC SIGNS NONE ES-ELECTRIC SIGNS NONE
May 17, 1993 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED