NYC Building Report

Bronx Westchester Square

2321 Glebe Avenue, Bronx

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

11 records

Date Status Type Summary
Feb 17, 2026 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL PROVIDE APPROXIMATELY 22 LINEAR FEET OF CONSTRUCTION FENCE @ EXPO#1 PROVIDE A 10 LINEAR FOOT RETURN @ EXPO# 4 TO FULLY CLOSE OFF THE POTE NTIAL HAZARD AND SAFEGUARD THE PUBLIC AND ADJACENT PROPERTY
Feb 14, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER DUE TO MULTIPLE CRACKS ON THE FRONT AND BOTTOM OF THE 2ND AND RED FLOOR BALCONIES AT EXPOSURE 1 OF BUILDING EXPOSURE 1 OF
Nov 10, 2025 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL REQUESTING AN ENGINEER REPORT DUE TO BALCONY'S BEING IN A STATE OF DISREPAIR. AN ENGINEERING REPORT IS REQUIRED TO ASSESS AND RECTIFY THE DAMAGES PROPERTY HAS SUSTAINED.
May 11, 2022 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Feb 11, 2022 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL ERECT AT EXPOSURE #1 APPROXIMATELY 40 LINEAR FEET OF SIDEWALK SHED AND .EXTEND AT EXPOSURE #2 AND #4 APPROXIMATELY 16 LINEAR FEET WITH A CATCHALL AT ALL THREE EXPOSURES TO SAFEGUARD PUBLIC AND PROPERTY
Mar 11, 2020 V%-DOB VIOLATION UB-UNSAFE BUILDINGS NONE UB-UNSAFE BUILDINGS NONE
May 25, 2010 VW*-VIOLATION - WORK W/O PERMIT DISMISSED C-CONSTRUCTION OTHER OPTIONAL WORK W/OUT PERMIT
May 26, 2009 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCS. NO STEEL BEAMS LALLY COLUMS INSTALLED. NO METAL. FLOOR JOISTS AS PER BUILDING SPECS . NO JOIST.2X12 OFFSET FOR ROOF.PITCH NOT SHOWN ON PUMP REMEDY: STOP ALL WORK. AMEND PLANS FOR ALL A/E APPROVED CHANGES. PR OVIDE A/E REPORT OF STRUCTURAL STABILITY CONTROLLED INSPECTIONS
May 20, 2009 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV ED AMENDMENTS THE PLANS SHOW METAL C JOISTS WOOD 2X12 JOISTS WERE INST ALLED AND NO JOISTS ANCHORAGE INSTALLED OR INDICATED ON PLANS 20099892 9 NB REMEDY: STOP ALL WORK SHOW ALL REQUIRED & CHANGES CONFORM TO AMEN DMENTS CALL 212 442-1544
May 20, 2009 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS THERE IS UNSAFE SCAFFOLDING @ THE FRONT NO GUARDRAILS NO ACCESS TO CELLAR & ROOF INADEQUATE FENCE 200998929NB REMEDY: SAFEGUARD PUBLIC & PROPERTY INSTALL SCAFFOLDING GUARDRAILS FENCE AS DOB REQUIRE MENTS ACCESS TO ALL FLOOR CALL 212 442-1838
Oct 10, 2006 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL