| Date | Status | Type | Summary |
|---|---|---|---|
| Dec 15, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | INADEQUATE DETAILS ON APPROVED PLANS FOR: BALCONY - STRUCTURAL SUPPORT & CONSTRUCTION. JOIST ANCHORAGE AT MASONRY WALLS, PARALLEL & PERPENDIC ULAR 72 INCHES ON CENTER. REMEDY: STOP ALL WORK. AMEND PLANS TO SHOW T HE ABOVE STRUCTURAL DETAILS AND FIRE DIVISION AT MASONRY WALLS. THEN CALL FOR RE-INSPECTION 212 442-1698/1544 |
| Nov 13, 2008 | V*-DOB VIOLATION - DISMISSED | C-CONSTRUCTION OTHER OPTIONAL | STOP ALL WORK MISCELLANEOUS VIOLATIONS FAILURE TO PROVIDE AT LEAST 4 I NCHES OF MASONRY BETWEEN COMBUSTIBLE FLOOR JOISTS FRAMED INTO A MASONR Y PARTY WALL NOTED: AT TIME OF INSPECTION WORK ON GOING UNDER PERMIT# 210024481 FRAMING SECOND FLOOR AND NO FIRE DIVISION PROVIDED AT PLANS REMEDY: STOP ALL WORK AMEND PLANS PROVIDE FIRE DIVISION DETAIL ON PLAN |