NYC Building Report

Bronx Mount Hope

2078 Morris Avenue, Bronx

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

14 records

Date Status Type Summary
Mar 13, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. RETAINING WALL ALONG EXP3 E EXHIBITS DEFECTIVE CONDITIONS. REMEDY: OWNER TO HIRE NYS-PE TO PREPARE ENGINEERING REPORT AND SUBMIT REPORT TO FACADES@BUILDINGS.NYC.GOV
Feb 18, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG R/W-@ EXP3 OF THE BLDG THE RUBBLE STONE R/W SHARED W/2075 CRESTON AVE & 2083 CRESTON AVE IS IN A STATE OF DISREPAIR W/DISJOINTED /MISSING STONE,DETERIORATED MORTAR JOINTS @ TOP FACE OF R/W. OWNER TO RETAIN NYSPE TO EVAL ENTIR R/W & FILE REPAIR DWGS W/DOB,R/W TO BE PERM REPAIRED UNDER PERMIT, START WORK BY 4/6/26
Feb 18, 2026 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FTM RETAINING WALL-@EXP3 OF THE BLDG THE RUBBLE STONE R/W SHARED W/ 2078 MORRIS AVE & 2084 MORRIS AVE IN A STATE OF DISREPAIR W/DISJOINTED /MISSING STONE,DETERIORATED MORTAR JOINTS@TOP FACE OF R/W.OWNER TO RETAIN NYSPE TO EVAL ENTIRE R/W & FILE REPAIR DWGS W/DOB,R/W TO BE PERM REPAIRED UNDER PERMIT START 4/6/26
Feb 14, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED RETAINING WALL ALONG EXP3E EXHIBITS DEFECTIVE CONDITINS INCLUDED (BULGED/DISPLACED STONES OF WALL STRUCTURE CRACKING & LOOSE STONES. REMEDY:OWNER HIRE NYS-PE:PREPARE AN ENGINEERING REPORT ADDRESSING CONDITIONS. OWNER SUBMIT ENGINEER REPORT FACADES@BUILDINGS.NYC.GOV NO LATER THAN 3/3/2026
Feb 14, 2026 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED RETAINING WALL ALONG EXP3E EXHIBITS DEFECTIVE CONDITINS INCLUDED (BULGED/DISPLACED STONES OF WALL STRUCTURE CRACKING & LOOSE STONES. REMEDY:OWNER HIRE NYS-PE:PREPARE AN ENGINEERING REPORT ADDRESSING CONDITIONS. OWNER SUBMIT ENGINEER REPORT FACADES@BUILDINGS.NYC.GOV NO LATER THAN 3/3/2026
Oct 1, 2019 V*-DOB VIOLATION - DISMISSED RWNRF-RETAINING WALL NONE FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09
Oct 1, 2019 V*-DOB VIOLATION - DISMISSED RWNRF-RETAINING WALL NONE FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09
May 3, 2012 V*-DOB VIOLATION - DISMISSED BENCH-FAILURE TO BENCHMARK NONE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Dec 2, 2010 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Jan 1, 2009 V-DOB VIOLATION - ACTIVE LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 19, 2003 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Mar 26, 2002 V*-DOB VIOLATION - DISMISSED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
Jul 1, 1997 V-DOB VIOLATION - ACTIVE LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL
Jul 1, 1992 V-DOB VIOLATION - ACTIVE LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL LL1080-LOCAL LAW 10/80 - FACADE FACADE OPTIONAL