Bronx Mount Hope
HPD violations
Housing Maintenance Code violations are filed by tax lot (BBL 2-03156-0003), so they can include other buildings on the same lot.
1644 records
| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Jan 6, 2020 | A | VIOLATION CLOSED | 3A | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM NORTH AT EAST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Jan 6, 2020 | A | VIOLATION CLOSED | 3A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Jan 6, 2020 | C | VIOLATION CLOSED | 3A | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Jan 6, 2020 | A | VIOLATION CLOSED | 3A | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Jan 6, 2020 | C | VIOLATION CLOSED | 3A | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Jan 6, 2020 | A | VIOLATION CLOSED | 3A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTION ERECTED FROM FLOOR TO CEALING SUBDIVIING ROOM IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''2060'', 1st FROM EAST AT SOUTH |
| Dec 11, 2019 | C | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERAYED DOOR LEADING TO THE FIRE ESCAPE WINDOW LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | B | VIOLATION CLOSED | 1G | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | B | VIOLATION CLOSED | 1G | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | C | VIOLATION CLOSED | 1G | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | C | VIOLATION CLOSED | 1G | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT THE DOOR LEADING TO THE FIRE ESCAPE WINDOW LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | B | VIOLATION CLOSED | 1G | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH AND WEST WALLS IN THE 4th ROOM FROM NORTH LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH |
| Dec 11, 2019 | C | VIOLATION CLOSED | 3D | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 3D, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM EAST AT SOUTH |
| Dec 11, 2019 | B | VIOLATION CLOSED | A | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM EAST AT SOUTH |
| Nov 22, 2019 | A | VIOLATION CLOSED | 2F | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Nov 22, 2019 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Nov 22, 2019 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT WEST AND SOUTH WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Nov 22, 2019 | B | VIOLATION CLOSED | 2F | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE KITCHEN LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH |
| Nov 13, 2019 | A | VIOLATION CLOSED | D | § 27-2005 ADM CODE REFIT AT APARTMENT ENTRANCE DOOR LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | C | VIOLATION CLOSED | D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | C | VIOLATION CLOSED | D | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE KITCHEN LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Nov 13, 2019 | B | VIOLATION CLOSED | D | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT D, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 30, 2019 | I | VIOLATION DISMISSED | Not available | § 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND VIOLATIONS RELATED TO THE ORDER. FAILURE TO COMPLY MAY RESULT IN EXTENSIVE REPAIR WORK TO CORRECT UNDERLYING CONDITIONS AND RELATED VIOLATIONS BY HPD. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WILL BECOME TAX LIENS ON THE PROPERTY |
| Oct 4, 2019 | B | VIOLATION CLOSED | F | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 4, 2019 | B | VIOLATION CLOSED | F | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 4, 2019 | B | VIOLATION CLOSED | F | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Oct 4, 2019 | B | VIOLATION CLOSED | F | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 23, 2019 | B | VIOLATION DISMISSED | LD | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE ... IN THE 1st ROOM FROM EAST LOCATED AT APT LD, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 23, 2019 | C | VIOLATION DISMISSED | LD | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT LD, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 23, 2019 | C | VIOLATION DISMISSED | LD | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL WALL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT APT LD, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 23, 2019 | C | VIOLATION DISMISSED | LD | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WROTTED UPPER WALL CABINET IN THE KITCHEN LOCATED AT APT LD, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 20, 2019 | B | VIOLATION CLOSED | A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE KITCHEN LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 20, 2019 | B | VIOLATION CLOSED | A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| Sep 20, 2019 | B | VIOLATION CLOSED | 1G | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1G, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 18, 2019 | B | VIOLATION CLOSED | 1E | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Sep 18, 2019 | A | VIOLATION CLOSED | 4E | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL IN THE BATHROOM LOCATED AT APT 4E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| Sep 11, 2019 | C | VIOLATION CLOSED | 3G | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 11, 2019 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Sep 11, 2019 | B | VIOLATION DISMISSED | 3G | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE DEVICE LOCATED AT APT 3G, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Sep 11, 2019 | B | VIOLATION DISMISSED | 3G | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE DEVICE LOCATED AT APT 3G, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |