NYC Building Report

Bronx University Heights (South)-Morris Heights

1931 Hennessy Place, Bronx

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

5 records

Date Status Type Summary
Aug 12, 2014 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL FAILURE TO COMPLY WITH COMMISSIONER ORDER #275157 REPAIR OF DEFECTIVE RETAINING WALL WAS ORDERED TO START NO LATER THAN APRIL 21, 2014 WORK PERMIT WAS ISSUED ON JUNE 10,2014 BUT NO WORK HAS STARTED. START WORK NO LATER THAN AUGUST 15, 2014
Jul 2, 2014 V*-DOB VIOLATION - DISMISSED AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
Apr 11, 2014 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL EXISTING RUBBLE RETAINING WALL APPROX.100'LONG X 35'HIGH X 2'-3'THICK LOCATED@REAR LOT LINE BETWEEN 1920 OSBOURNE PL(LOWER)& 1931 HENNESSYPL (HIGHER).APPROX.25'X15' SURFACE AREA OF WALL COLLAPSED INTOREAR YARD OF 1920 OSBOURNE PL.STABILITY OF RW IS UNPREDICTABLE.REQUIRELIC PE TO INSPECT ENTIRE RW&FILE PLANS/PERMITS BY 4/18,START REPAIRS BY 4/21/14
Apr 8, 2014 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL FAIL TO MAINTAIN.GARAGE@REAR OF LOT IS DEFECTIVE STRUCTURALLY DUE TO SEVERELY CRACKED EXP.#4 WALL&EXP.#3 COMPROMISED FOUNDATION@COLLAPSED RW. OWNER TO IMMEDIATELY HAVE LIC PE EVALUATE GARAGE, SUBMIT STABILITY REPORT TO DOB FEU BY 4/14/14 & OBTAIN PERMIT/REPAIR/REPLACEMENT OF GAR START REPAIR/REPLACEMENT WORK NO LATER THAN 4/28/14
Apr 7, 2014 V*-DOB VIOLATION - DISMISSED IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL