Bronx University Heights (South)-Morris Heights
1930 Loring Place South, Bronx
DOB violations
Department of Buildings violations attached to this BIN or tax lot.
4 records
| Date | Status | Type | Summary |
|---|---|---|---|
| Sep 4, 2026 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | REMEDY: PROVIDE A SIDEWALK SHED ACROSS THE ENTIRE LENGTH OF.EXPOSURE 1 APPROXIMATELY 42 LINEAR FEET, INCLUDING 5 FEET BEYOND EACH SIDE OF THE PROPERTY LINE |
| Sep 2, 2026 | V*-DOB VIOLATION - DISMISSED | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | REMEDY: INSTALL AN 8-FOOT-HIGH CONSTRUCTION FENCE AS FOLLOWS: 1 EXPO 4:APPROX 10 FT OF CONSTRUCTION FENCE. 2 EXPO 1: ACROSS THE ENTIRE EXPO, APPROX 32 FT, 3 EXPO 2: ALONG THE SHARED DRIVEWAY FOR THE ENTIRE LENGTH OF THE PROPERTY LINE, APPROXIMATELY 125 FT |
| Sep 2, 2026 | V-DOB VIOLATION - ACTIVE | UB-UNSAFE BUILDINGS NONE | UB-UNSAFE BUILDINGS NONE |
| Sep 2, 2026 | V-DOB VIOLATION - ACTIVE | C-CONSTRUCTION OTHER OPTIONAL | ENGINEERS REPORT REQUESTED : "FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. FACADE AT EXP 1,2,3 HAS STEP/VERTICAL CRACKS, MISSING BRICK/MORTAR .AT SHARED DRIVEWAY MISSING CONCRETE & FRONT STEPS SEMI-COLLAPSING WITH MISSING CONCRETE CHUNKS AT RISER STEPS & HOLES. RETAINING WALL HAS CRACKS & OPEN WINDOWS CAUSING WATER INTAKE. |