NYC Building Report

Bronx Mount Hope

1762 Monroe Avenue, Bronx

DOB violations

Department of Buildings violations attached to this BIN or tax lot.

13 records

Date Status Type Summary
Oct 28, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DEPT. RECEIVED PE'S REPORT NOTING THAT ADDITIONAL BRACING & MONITORING POINTS ARE REQUIRED REMEDY: INSTALL REQUIRED MONITORING POINTS.PROVIDE WEEKLY MONITORING REPORTS
Oct 7, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DEPT. RECEIVED PE'S REPORT NOTING THAT ADDITIONAL BRACING & MONITORING POINTS ARE REQUIRED. REMEDY: INSTALL REQUIRED BRACING AND MONITORING POINTS. SUBMIT PE REPORT CERTIFYING STABILIZATION WORK
Oct 4, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Apr 24, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DEPT RECEIVED PE REPORT NOTING WORK REQUIRED TO SAFEGUARD SITE
Apr 24, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DEPT RECEIVED PE REPORT NOTING UNDOCUMENTED IN-PLACE.UNDERPINNING REMEDY: RETAIN NYS PE TO PREPARE PLANS DOCUMENTING THE IN SITU UNDERPINNING. PERFORM REQUIRD INVESTIGATN. SUBMIT PLANS BY 5/31/24
Apr 24, 2024 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL DEPT RECEIVED PE REPORT RECOMMENDING PERIODIC INSPECTION & OPTICAL MONITORING. REMEDY: RETAIN NYS PE TO PERFORM TO PROVIDE MONTHLY INSPECTION REPORTS. PERFORM OPTICAL MONITORING
Nov 1, 2023 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL PARTIAL DEMOLITION CREATED UNBRACED CONDITION FOR PERIMETER BRICK MASONRY WALLS REMEDY: RETAIN REGISTERED DESIGN PROFESSIONAL TO PREPARE STRUCTURAL STABILITY REPORT. SUBMIT REPORT BY 11/15/2023
Oct 25, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Oct 17, 2022 V-DOB VIOLATION - ACTIVE C-CONSTRUCTION OTHER OPTIONAL C-CONSTRUCTION OTHER OPTIONAL
Aug 17, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL THE DEPARTMENT OF BUILDINGS ORDERS THAT YOU STOP ALL WORK UNDER THE PERMIT# 210180212-01-AL-03 DUE TO PERMIT HOLDER WITHDRAWAL FROM THE PROJECT.
Aug 17, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL THE DEPARTMENT OF BUILDINGS ORDERS THAT YOU STOP ALL WORK UNDER THE PERMIT# 210180212-01-AL-03 DUE TO PERMIT HOLDER WITHDRAWAL FROM THE PROJECT.
Aug 17, 2022 V*-DOB VIOLATION - DISMISSED C-CONSTRUCTION OTHER OPTIONAL THE DEPARTMENT OF BUILDINGS ORDERS THAT YOU STOP ALL WORK UNDER THE PERMIT# 210180212-01-AL-03 DUE TO PERMIT HOLDER WITHDRAWAL FROM THE PROJECT.
Dec 22, 2021 V-DOB VIOLATION - ACTIVE AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION